Chilled/Hot Water Exchanger Pressure Drop - Trane Sintesis Balance CMAF Installation Operation & Maintenance

Air-to-water multi-pipe scroll unit
Table of Contents

Advertisement

Chilled/hot water exchanger pressure drop

Figure 10 – CMAF chilled/hot water exchanger Water Pressure Drop according BPHE plate number
FWD
Power supply
Capacities
Cooling capacity on water (1)
Heating capacity on water (2)
Fan motor
Fan power input (3)
Current amps (3)
Start-up amps
Air flow
minimum
nominal
maximum
Main coil
Water entering/leaving connections
Electric heater (accessory for blower only)
Electric power supply
Heating capacity
Hot water coil (accessory for blower only)
Heating capacity (4)
G2 filter (filter box accessory)
Quantity
Dimensions ( LxWxth)
G4 filter (filter box accessory)
Quantity
Dimensions ( LxWxth)
Condensate pump (accessory)
Water flow - lift height
Not available for FWD30 and FWD45
Pressure drop depends of the number of plate of the Brazed Plate Heat Exchanger:
Sound level (L/M/H speed)
Sound pressure level (5)
Table 11 - Plate number of CMAF Chilled / Hot Water Exchanger
Sound power level (5)
Unit dimensions
Width x Depth
Unit Size
Height
Shipped unit dimensions
Chilled water
Width x Depth
Hot Water
Height
Weight
Colour
Note: Water pressure drop are for pure water. Acceptable water flow rate is 1.4 to 4.2 l/(min.kW) for chilled water
Recommended fuse size
loop and 0.9 to 4.2 l/(min.kW) for hot water loop. the rating flow rate is 2.9 l/(min.kW) in order to maintain 5K of
Unit alone (aM/gI)
temperature difference between entering and leaving water temperature.
Unit with electric heater (gI)
Flow rates over 4.2 l/(min.kW) will cause excessive erosion.
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
Flow rates below the minimum recommendation must be avoided to avoid laminer flow, potential exchanger
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
freezing scaling and poor temperature control.
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Heat exchanger operating limits:
FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
36
4
Technical Data
08
(V/Ph/Hz)
(kW)
5,2
(kW)
6,3
(type)
(kW)
0,23
(A)
1,1
(A)
3,2
(m
/h)
490
3
(m
/h)
820
3
(m
/h)
980
3
(type)
(Dia)
3/4"
(V/Ph/Hz)
230/1/50
(kW)
2/4
(kW)
6,3
2
(mm)
386x221x8
-
(mm)
-
(type)
(l/h - mm)
(dB(A))
36/40/43
(dB(A))
46/50/53
(mm)
890 x 600
80
90
100
110
(mm)
250
106
138
138
166
(mm)
933 x 644
138
166
166
194
(mm)
260
(kg)
32
(A)
8/16
(A)
16 (2kW),25 (4kW)
12
230/1/50
8,3
11,9
18,9
2 x direct drive centrifugal
0,46
0,65
2,2
5,5
980
1400
1650
2300
1970
2600
ISO R7 rotating female
3/4"
1 1/2"
230/1/50 or 400/3/50
400/3/50
8
12
2
486x271x8
586x321x8
2
486x264x48
586x314x48
Centrifugal
24 - 500
38/41/44
46/50/53
48/51/54
56/60/63
1090 x 710
1290 x 820
130
140
150
165
180
300
194
194
222
250
250
1133 x 754
1333 x 864
222
222
250
278
278
310
46
galvanised steel
8/16
8/16
40 (230V),3*16 (400V)
3*20
20
30
15
18,8
30,1
20,9
38,2
1,04
1,51
3,1
4,7
9,3
14,1
16,5
1800
2700
3000
4500
3600
5400
1 1/2"
1 1/2"
400/3/50
400/3/50
10
12
17,4
22,4
34,5
2
2
586*421*8
586*621*8
2
2
586*414*48
586*614*48
47/52/57
47/52/58
57/62/67
57/62/68
1290 x 970
1290 x 1090
190
350
450
650
278
1333 x 1008
1333*1133
294
360
460
660
61
76
8/25
8/25
3*25
3*25
UNT-PRC002-GB
CG-SVX051A-GB
45
5,5
12
2
2
118