Installation Instructions 0 to 100% Downflow Dry Bulb Economizer Packaged Cooling and Gas/Electric 12.5 to 25 Tons Model Number: Used With: FIAECON003* T/YS*180-300, W/D/GS*150-300 SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training.
Page 2
Practices with OSHA, NFPA 70E, or other country-specific requirements for arc flash protection, PRIOR to Trane believes that responsible refrigerant practices are servicing the unit. NEVER PERFORM ANY important to the environment, our customers, and the air SWITCHING, DISCONNECTING, OR VOLTAGE conditioning industry.
Page 3
Copyright This document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission. Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change.
General Information Inspection 5. Do not remove damaged material from the receiving location. Take photos of the damage, if possible. The 1. Unpack all components of the kit. owner must provide reasonable evidence that the 2. Check carefully for shipping damage. If any damage is damage did not occur after delivery.
Installation 2. Remove the filter/fan compartment access panel and the unit end panel (evaporator end). WARNING Hazardous Service Procedures! Figure 3. Remove panels Failure to follow all precautions in this manual and on the tags, stickers, and labels could result in death or serious injury.
Page 7
Installation 3. Block-off installation b. Place the economizer assembly into the opening with the back right flange, on the economizer, a. Attach block-off 5 to unit using four screws as behind the corner post flange, as illustrated in illustrated in Figure following figure.
Installation 5. Attach end panel back to unit. Figure 11. Pull economizer assembly outward Figure 9. Attach end panel Block-off Angle Remove screws and lay block-off angle aside. Factory Installed Option 4. Do not remove the screws in the upper row of the end (Field Set-Up) panel.
Installation 8. Install the block-off angle underneath the economizer. 11. Using field supplied silicone sealant, seal all seams, Refer to Figure 13. The block-off angle is designed to cracks and gaps around the back panel and vertical close the opening created between the economizer edge of the hood panels.
Installation Minimum Position Setting seconds without movement, it can be assumed it is at the new position. To adjust the minimum position setting and check out the 3. Replace the filter access panel. economizer, the power must be connected. The damper will close when the blower circuit is 1.
Page 12
For more information, please visit trane.com or americanstandardair.com. Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.