Controls/Tracer Td7 Operator Interface - Trane Sintesis Balance CMAF Installation Operation & Maintenance

Air-to-water multi-pipe scroll unit
Table of Contents

Advertisement

Controls Overview
CMAF units use the following control/interface
components:
Symbio™ Controller
Sound power levels
Tracer TD7 Operator Interface
Communication Interfaces
Discharge
There are four connections on the Symbio™ that
Measurement conditions:
support the communication interface. See CMAF User
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
Guide to locate the following ports: "Wiring and Ports
long) fixed to its discharge opening.
Description" section.
BACnet MS/TP and BACnet IP
Fan
MODBUS RTU (Slave) and Modbus TCP (Slave)
Unit
speed
1
See User Guide for information on communication
FWD 08
2
interface.
3
1
Tracer TD7 Operator Interface
FWD 10
2
3
Operator Interface
1
FWD 12
2
Information is tailored to operators, service technicians
3
and owners. When operating a Multi-Pipe unit, there is
1
specific information you need on a day-to-day basis, like
FWD 14
2
setpoints, limits, diagnostic information, and reports.
3
1
Day-to-day operational information is presented at the
FWD 20
2
display. Logically organized groups of information-
3
Multi-Pipe unit mode of operation, active diagnostics,
Intake
settings and reports put information conveniently at your
fingertips.
Measurement conditions:
Tracer™ TU
Measurements taken at the horizontal air intake.
The TD7 operator interface allows for daily operation
Fan
tasks and set point changes. However to adequately
Unit
speed
service Sintesis CMAF Multi-Pipe units, Tracer™TU
1
service tool is required (Non-Trane personnel,
FWD 08
2
contact your local Trane office for software purchase
3
1
information). Tracer™
FWD 10
2
TU adds a level of sophistication that improves service
3
technician effectiveness and minimizes unit downtime.
1
FWD 12
2
This portable PC-based service-tool software supports
3
service and maintenance tasks.
1
FWD 14
2
Tracer™ TU Set-Up
3
1
Using Tracer™ TU service tool, adjust the settings. Refer
FWD 20
2
to Tracer™ TU manual and Tracer Symbio™ 800 user
3
guide for instruction on settings.
CAUTION! To prevent compressor damage, do not
operate the unit until all refrigerant valves and oil-line
service valves are opened.
IMPORTANT! A clear sight glass alone does not mean
that the system is properly charged. Also check system
discharge superheat, approach temperature and unit
operating pressures.
CG-SVX051A-GB
UNT-PRC002-GB

Controls/Tracer TD7 Operator Interface

Power level in dB(A), per Hz frequency band
125
250
500
55
50
42
57
54
47
58
57
50
57
51
45
58
54
48
60
58
50
57
51
45
58
54
48
60
58
50
56
62
50
61
66
55
63
69
58
57
63
51
61
66
55
63
69
58
Power level in dB(A), per Hz frequency band
125
250
500
56
55
55
63
62
60
66
65
63
62
58
55
66
63
60
70
67
63
62
58
55
66
63
60
70
67
63
66
65
65
73
72
69
78
76
73
68
72
64
76
76
68
78
79
71
1000
2000
4000
37
37
31
40
30
38
42
32
40
42
34
33
45
38
39
48
40
42
42
34
33
45
38
39
48
40
42
48
39
38
53
47
46
56
50
50
49
40
39
53
47
46
56
50
50
1000
2000
4000
53
46
45
60
53
53
62
56
55
58
51
48
62
56
55
65
59
59
58
51
48
62
56
55
65
59
59
65
57
50
71
64
59
75
69
64
64
56
52
71
65
61
74
69
66
Overall power
8000
dB(A)
30
46
40
50
43
53
28
48
35
51
39
54
28
48
35
51
39
54
36
56
45
60
49
63
37
57
45
60
49
63
Overall power
8000
dB(A)
42
57
53
64
57
67
44
61
52
66
57
69
44
61
52
66
57
69
46
68
57
74
63
78
50
69
61
75
66
78
11
53