Service Diagnostics and Procedures

Side Burner

The side burner is available on some models. When
the side burner valve is turned on, gas begins to
flow and the spark switch sends a spark to the
igniter. This spark comes in contact with the gas
and creates ignition.
To access the side burner:
1. Remove grates, burner bowls, and grate
support.
2. Remove screws securing burner.
3. Lift burner and separate air shutter from orifice.
© 2009 Viking Preferred Service
4. Disconnect igniter wire and remove burner.
Igniter Wire
5. Remove two screws securing igniter to burner.
6. Reverse procedure to reassemble.
If burner does not ignite, verify spark and gas flow
at burner. Visually look for a spark at the burner. If
no spark is found, ohm igniter and verify no cracks.
If igniter is proper verify spark switch wiring and
power source. If power is supplied, spark wires are
intact and still no spark, replace the spark switches.
If no gas is available, make sure the gas is turned on
and the supply is available. If supply is proper and
still no flow verify gas valve and orifice. If orifice
or air shutter is not plugged and still not flowing,
replace the gas valve.
Screws
25