Chapter 4
Technical Specifications
Section 4.2
PoE Power Supply Specifications
Power Supply Type
48 VDC
e
(T) denotes time-delay fuse.
Section 4.3
Failsafe Relay Specifications
Rated Switching Current
Section 4.4
Copper Ethernet Port Specifications
The following details the specifications for copper Ethernet ports that can be ordered with the RX1000P.
f
Speed
10/100Base-TX
f
Auto-negotiating.
g
Shielded or unshielded.
h
Auto-crossover and auto-polarity.
i
RMS 1 minute.
Section 4.5
Serial Port Specifications
Baud Rate
300 to 230 kbps
34
Input Range
Minimum
37 VDC
Parameter
Max Switching Voltage
f
Connector
Duplex
RJ45
FDX/HDX
Internal Fuse Rating
Maximum
72 VDC
1 A @ 30 VDC, 0.3 A @ 80 VDC
Wiring
g
Cable Type
h
Standard
TIA/EIA
> CAT- 5
T568A/B
Connector
RJ45
DB25
RUGGEDCOM RX1000P
Installation Guide
Maximum Power
e
Consumption
2 A(T)
Value (Resistive Load)
30 VAC, 80 VDC
0.3 A @ 30 VAC
Maximum
PoE
i
Isolation
Distance
Voltage
100 m
1.5 kV
44-57 V
(328 ft)
Isolation
2.5 kV
PoE Power Supply Specifications
68 W
PoE
Current
350 mA