Diagnosing the KUADRO Electric Management System
Safety 3 communication line (diagnosis of
P0600
SPI communication line between DSP and
PPC)
P0602
Internal communication line
P0A00
Electric motor temperature
P0A01
Electric motor temperature sensor
P0A02
Inverter current "V" phase
P0A03
Inverter current "W" phase
P0A04
High voltage bridge temperature
ERRORS
In the event of a fault, attempt reprogramming, then replace INVERTER if
necessary
In the event of a fault, attempt reprogramming, then replace INVERTER if
necessary
If this error is indicated, check the electric motor temperature sensor by
allowing the motor to cool to ambient temperature and measuring the
electric motor temperature sensor resistance values as indicated in the
manual
Indicatively, the sensor operates within a range from -5°C and +110°C
(with a tolerance of ± 10°C). The self-diagnosis system identifies an "open
circuit" fault state. (In reality, the system receives no indication of a
temperature increase during use, so the temperature value remains at -4/-
5°C). In the event of short circuit, self-diagnosis is not activated and
instead, a temperature value of 130°C is indicated on the Navigator,
which does not drop even while the motor is effectively cooling. The
system nonetheless cuts out due to motor overheating, the mains charge
indicator lamp lights and the electric motor cuts out. In the event of a
fault, carry out the checks described in the service station manual.
This error is generated if electric motor phase current is higher than +45A or
lower than -45A. Check phases with a multimeter as described in the SSM
This error is generated if electric motor phase current is higher than +45A or
lower than -45A. Check phases with a multimeter as described in the SSM
If value not within range between -50° and + 200°, replace INVERTER
INT
INT
EXT
EXT
INT
INT
INT
45