4
|
About the box

4.3.1 To unpack the indoor unit

4.3.2 To remove the accessories from the indoor unit

4.3.3 To handle the indoor unit

Installer reference guide
26
Unpack the indoor unit completely according to the instructions mentioned on
the unpacking instructions sheet.
1
j
a Shut-off valves for water circuit
b Overpressure bypass valve
c Tundish (to mount onto the pressure relief valve discharge pipe)
d Brass compression coupler
e Discharge pipe (for pressure relief valve)
f General safety precautions
g Addendum book for optional equipment
h Indoor unit installation manual
i Operation manual
j WLAN cartridge
k Sealing rings for shut-off valves (space heating water circuit)
l Sealing rings for field-supplied shut-off valves (domestic hot water circuit)
m Sealing tape for low voltage wiring intake
Use the handles at the back and at the bottom to carry the unit.
2
a
b
c
d
f
g
h
i
k
l
m
e
EPRA08~12EAV3+W1 + ETVH12SU18+23EA6V
Daikin Altherma 3 H MT F
4P644482-1 – 2021.03