Technical Specification Trouble Shooting Important information The SPARTAN series of explosion protected floodlights are specialist devices, certified for use in specific operating environments. The units must be installed in accordance with these instructions, must be correctly certified for the specific operating environment and must be installed by suitably qualified personnel.
If the last charge date was in excess of 3 months (if stored at 5 C to ° C) or 1 month (if stored outside this range) from date of installation, please ° consult Raytec document 0010-D-00001 Battery Handling Guide 1.5m Install in a well Do not continually Isolate mains before...
Mounting SPARTAN Unit 1. To meet the requirements of certification a MINIMUM of 2 fixing points must be used, the fixing points must be suitable for the conditions of use. Raytec recommend using M8 Marine Grade A4 Stainless Steel fixings (not supplied)
Page 4
Spartan 48 2. The SPARTAN floodlight and the mounting bracket is supplied together as a unit. The bolts in the side of the housing shall be removed and used to secure the bracket to the SPARTAN housing, the bracket can be attached in the top or bottom position depending on the mounting application, where possible the cable glands should be kept to the bottom of the floodlight.
Page 6
3. Open the rear compartment to access terminal block. Wire the Mains cable into the terminal block. Provision has been made for this and identified as the E (Earth), L1 (swiched live) and L2 (permanent live) and N (Neutral) terminals. There are two pairs of contacts for each of these to facilitate a mains cable that can be looped in and out of the unit.
3. Maintenance 1. It is essential that all SPARTAN units are maintained in accordance with the requirements of the EN60079-17 standard: (Electrical apparatus for explosive gas atmospheres – other than mines). 2. IMPORTANT. No modifications are permitted to the unit, all spare parts must be purchased from the manufacturer, unauthorized modifications or spare parts will invalidate certification and make the equipment dangerous.
4. Technical Specification Spartan 12 Spartan 24 Spartan 48 Input Voltage 110-254V AC or 18-48V AC/18-69V DC or 12V DC Consumption 34W max 68W max 136W max Consumption 139W max 71W max (Emergency variant) Power Factor >0.95 Mains Frequency 50/60Hz Inrush Current (Ipeak @ 50%) 40A ∆t <...
5. Trouble Shooting 1. Ensure the two LED boards are correctly wired to terminal block. White to White : White/Red to White/Red 2. Ensure Mains input is correctly connected. 3. Ensure Mains Input is turned on at the source 4. On emergency variants check fuse to ensure it has not blown 5.
Page 10
& UK Directive SI 2016 No. 1107 (as amended) Raytec Ltd. declares under our sole responsibility that the product(s) listed below conform with the relevant provisions of directive 2014/34/EU of 20th April 2016 and UK Directive SI 2016 No. 1107 (as amended)
Page 11
Compliance with the Essential Health and Safety Requirements has been assessed by reference to the following harmonised/designated standards - EN 60079-0 : 2018 EN 60079-7 : 2015 + A1 : 2018 EN 60079-18 : 2015 + A1 : 2017 EN 60079-31 : 2014 EN 60079-1 : 2014 And also 2014/35/EU - Low Voltage Directive, 2014/30/EU - EMC Directive Signed...