Raytec SPARTAN Series Installation Manual

Raytec SPARTAN Series Installation Manual

Floodlight range
Hide thumbs Also See for SPARTAN Series:

Advertisement

SPARTAN
Floodlight Range Installation Guide
CML13ATEX3007 IEC Ex CML14.0001
This installation guide provides instructions for installing the Infra-Red and
White-Light SPARTAN SPX series of explosion protected floodlights.
Text in Bold is specific for emergency variants
Overview
Important information
The SPARTAN series of explosion protected floodlights are specialist devices,
certified for use in specific operating environments.
The units must be installed in accordance with these instructions, must be correctly
certified for the specific operating environment and must be installed by suitably
qualified personnel.
Emergency floodlights will require the fuse to be reconnected upon
installation and the floodlight subjected to three 24 hour charge/discharge
cycles to bring the battery up to peak capacity.
If you have any queries about the installation or the certification of the unit – please
contact Raytec for immediate assistance and advice.
1
Safety Instructions
2
Installation
3
Maintenance
4
Technical Specification
5
Trouble Shooting

Advertisement

Table of Contents
loading

Summary of Contents for Raytec SPARTAN Series

  • Page 1 Technical Specification Trouble Shooting Important information The SPARTAN series of explosion protected floodlights are specialist devices, certified for use in specific operating environments. The units must be installed in accordance with these instructions, must be correctly certified for the specific operating environment and must be installed by suitably qualified personnel.
  • Page 2: Safety Instructions

    3. If the SPARTAN unit is to be installed in areas of high vibration, please consult with Raytec. 4. The SPARTAN unit housing is constructed from marine grade aluminium and toughened glass. The end user must ensure that these materials are suitable for the environment the SPARTAN unit will be installed in;...
  • Page 3: Installation

    2. Installation Mounting SPARTAN Unit 1. To meet the requirements of certification a MINIMUM of 2 fixing points must be used, the fixing points must be suitable for the conditions of use. Spartan 12 Floodlight Spartan 24 (Emergency Variant Shown) UK / Europe Tel: +44 (0) 1670 520055 www.rayteccctv.com Americas Tel: +1 613 270 9990...
  • Page 4 Spartan 48 2. The unit may have been supplied with an integrated photocells. Care should be taken when positioning the unit to ensure the sensors are not shielded, is not pointing directly at another light source and is monitoring the general, prevailing light conditions.
  • Page 5 Typical wiring diagram – standard luminaires Typical wiring diagram – emergency luminaires UK / Europe Tel: +44 (0) 1670 520055 www.rayteccctv.com Americas Tel: +1 613 270 9990...
  • Page 6 4. Wire the Mains cable into the terminal block. Provision has been made for this and identified as the E (Earth), L (Live), Ls (Live switched) and N (Neutral) terminals. There are two pairs of contacts for each of these to facilitate a mains cable that can be looped in and out of the unit.
  • Page 7: Maintenance

    3. Maintenance 1. It is essential that all SPARTAN units are maintained in accordance with the requirements of the EN60079-17standard: (Electrical apparatus for explosive gas atmospheres – other than mines). 2. IMPORTANT. No modifications are permitted to the unit, all spare parts must be purchased from the manufacturer, unauthorized modifications or spare parts will invalidate certification and make the equipment dangerous.
  • Page 8: Technical Specification

    4. Technical Specification Spartan 12 Spartan 24 Spartan 48 Input Voltage 110-254V AC Consumption 30W max 60W max 120W max Consumption 125W max 65W max (Emergency variant) Power Factor >0.95 Mains Frequency 50/60Hz IP Rating IP66/67 Weight Environment 5kg (11lbs) 9.5kg (20.9lbs) 19kg (41.9lbs) Weight Environment...
  • Page 9: Troubleshooting

    5. Trouble Shooting 1. Ensure the two LED boards are correctly wired to terminal block. White to White : Violet to Violet 2. Ensure Mains input is correctly connected. 3. Ensure Mains Input is turned on at the source 4. On emergency variants check fuse to ensure it has not blown 5.
  • Page 10 Spartan: White Light Max Lighting Part Code Description Distance* SPX-FL12-W-1010 Spartan Flood, 12 LED, White-Light, 10˚x10˚ SPX-FL12-W-3030 Spartan Flood, 12 LED, White-Light, 30˚x30˚ SPX-FL12-W-5050 Spartan Flood, 12 LED, White-Light, 50˚x50˚ SPX-FL12-W-120120 Spartan Flood, 12 LED, White-Light, 120˚x120˚ SPX-FL24-W-1010 Spartan Flood, 24 LED, White-Light, 10˚x10˚ 132m SPX-FL24-W-3030 Spartan Flood, 24 LED, White-Light, 30˚x30˚...
  • Page 11 Spartan: Infra-red Max Lighting Part Code Description Distance* SPX-FL12-I-1010 Spartan Flood, 12 LED, Infra-Red, 10˚x10˚ 230m SPX-FL12-I-3030 Spartan Flood, 12 LED, Infra-Red, 30˚x30˚ 112m SPX-FL12-I-5050 Spartan Flood, 12 LED, Infra-Red, 50˚x50˚ SPX-FL12-I-120120 Spartan Flood, 12 LED, Infra-Red, 120˚x120˚ SPX-FL24-I-1010 Spartan Flood, 24 LED, Infra-Red, 10˚x10˚ 325m SPX-FL24-I-3030 Spartan Flood, 24 LED, Infra-Red, 30˚x30˚...
  • Page 12 Typircal Spare Parts: 24 - 48 variants Part Code Description SFL-PSUL-STD-T4 PSU Left hand SFL-PSUR-STD-T4 PSU Right hand SFL-PSUL-EMER-T4 Emergency PSU Left hand SFL-PSUR-EMER-TR Emergency PSU Right hand SFL-LE-MW-1010 White LED Assembly 10x10 SFL-LE-MW-3030 White LED Assembly 30x30 SFL-LE-MW-5050 White LED Assembly 50x50 SFL-LE-MI-1010 IR LED Assembly 10x10 SFL-LE-MI-3030...
  • Page 13 Declaration Of Conformity With The Atex Directive 94/9/Ec Raytec Ltd. declares under our sole responsibility that the product(s) listed below conform with the relevant provisions of directive 94/9/EC of 23rd March 1994 Manufacturer Raytec Ltd Unit 3, Wansbeck Business Park...
  • Page 14 Compliance with the Essential Health and Safety Requirements has been assessed by reference to the following standards - IEC 60079-0 : 2012 IEC 60079-7 : 2007 IEC 60079-18 : 2009 IEC 60079-31 : 2009 And also 89/336/EEC – Electromagnetic Compatibility Signed Name Barry Thompson...
  • Page 15 UK / Europe Tel: +44 (0) 1670 520055 www.rayteccctv.com Americas Tel: +1 613 270 9990...
  • Page 16 UK / Europe T: +44 (0) 1670 520055 F: +44 (0) 1670 819760 sales@rayteccctv.com Americas (Toll Free) T: +1 888 505 8335 ussales@rayteccctv.com www.rayteccctv.com SP/14/8.1...

Table of Contents