5> Flow Adjustment In High Temperature Segment - S&A CW-6000AN250S01 User Manual

Dual temperature industrial chiller
Table of Contents

Advertisement

7.
Advanced parameters adjustment cases:
Order
Code
Temperature
1
F0
Temperature
2
F1
Difference values
3
F2
4
F3
Way of control
Alarm for over high
5
F4
water temperature
Alarm for over low
6
F5
water temperature
Alarm for over high
7
F6
Room temperature
8
F7
The allowed highest
9
F8
water temperature
The allowed lowest
10
F9
water temperature
(1) Case 1: cooling water temperature is controlled by constant mode. Requiring
water temperature is constant in 28℃, and the fluctuate does not exceed ± 2℃.
The alarm of over high water temperature will be on when water temperature is
5℃ higher than normal value, and the alarm of over low water temperature will
be on when water temperature is 10 ℃ lower than normal value. It is
convenient for user to adjust the water temperature between 5-30℃.
(2) Case 2: cooling water temperature is controlled by constant mode. Requiring
water temperature is constant in 20℃, and the fluctuate does not exceed ± 1℃.
The over high water temperature will be on when water temperature is higher
than 25℃, and the alarm of over low water temperature will be on when water
temperature is lower than 5℃. (Regardless of what is the ambient temperature,
the cooling water temperature is constant in 19℃ to 21℃)
<5>
Flow adjustment in high temperature
segment
After long-term testing, 1~1.5 L/min flow rate in high temp segment is the best for
cooling laser optics.
Value in
Item
case 1
28
setting
Cooling
2.0
hysteresis
10
45
Password
30
CW-6000/6100/6200 Series
Value in
Temperature
case 2
controller
Factory Setting
20
1.0
0
0
5
4
14
45
8
8
30
5
5
9
T-506
T-506H
Temperature
controller
Factory Setting
30
25
-2
-2
0.1
0.3
1
0
10
10
15
15
45
45
8
8
35
30
20
20