Install The Sliding Rail Assemblies; Install The Server - Dell EMC VxFlex Ready Node 13G Hardware Installation Manual

Hide thumbs Also See for EMC VxFlex Ready Node 13G:
Table of Contents

Advertisement

Install the sliding rail assemblies

Procedure
1. Insert the ends of the chassis rails into the front of the rails mounted to the
cabinet and push the server into the cabinet (1).
2. Depending on the rail configuration, the latches on the front of the server
engage automatically (2). If the latches do not engage automatically, secure the
server in the cabinet by tightening the screw under each latch (3).
3. Connect I/O and power cables as described in your system cabling
documentation.
4. Thread the Velcro straps through the slots on the back brackets and use the
Velcro straps to secure the cables (4).
Note
To remove the server from the cabinet, pull the server out until the travel stops
are reached. Locate the blue tabs on the sides of the chassis rails. Push the
tabs inward and pull the server until the chassis rails are clear of the rails (5).
The travel stop position is intended for repositioning your grip for server
removal. It is not intended for service. You must be prepared to support the
weight of the server when the chassis rails separate from the cabinet rails
Figure 27 Install the server
This procedures describes installation of the sliding rail assemblies in the cabinet.
Procedure
1. Position the left and right rail end pieces labeled FRONT facing inward and
orient each end piece to seat in the holes on the front side of the vertical
cabinet flanges (1).
2. Align each end piece in the bottom and top holes of the desired U spaces (2).
2U1N Configuration Equipment Installation

Install the sliding rail assemblies

65