7.3 Stop Current Selection

Stop Current means the motor current value automatically set in 0.1 sec after motor stops.
This is to prevent the overheat ot a motor when the motor is under long time idling. Select a
desired Stop Current by pressing in
screen. The range of this value is 10~100 and the unit is a percentage.
Press button to save the value selected into the drive.
※ The default factory setting is 50%.

7.4 Rotational Direction Selection

The direction of the motor rotation can be selected either in CW(Clockwose) or in CCW(Count
er Clockwise). Select a desired rotation direction by pressing
button on Ezi-STEP BT Setting screen.
Press button to save the value selected into the drive.
※ The default factory setting is CW(Clockwise).

7.5 Pulse Input Selection

As the Pulsed inputs, a user can choose One-pulse-mode(Pulse/Dir) or two-pulse-
mode(CW/CCW). Select a desired pulse mode by pressing
on Ezi-STEP BT Setting screen.
Press button to save the value selected into the drive.
※ The default factory setting is two pulse input mode(CW/CCW).

7.6 Alarm Reset Input Selection

Input method of Motor Free/Alarm Reset can be selected. Select a desired method by
pressing
in
Press button to save the value selected into the drive.
※ The default factory setting is Nomal.
※ Caution : When you select 'Inverse' :
It can be 'Motor Free' status when power is applied to Ezi-STEP BT during Signal Connector(CN2) is not
connected. The power LED(green) is flash to show the status of 'Motor Free'
www.fastech.co.kr - 18
button on Ezi-STEP BT Setting screen.
button on Ezi-STEP BT Setting
in