Resolution; Stop Current; Pulse Mode; Rotation Direction - Fastech Ezi-STEP-BT-42 Series Operating Manual

Table of Contents

Advertisement

Fastech Co.,Ltd.

7.2.1 Resolution

Resolution means the number of pulses per one rotation of a motor.
Select a desired resolution by pressing
screen. The possible resolution values are 500, 1000, 1600, 2000, 3200, 3600, 4000, 5000,
6400, 8000, 10000, 20000, 25000, 36000, 40000, 50000.
Press
* The default factory setting is 10,000 [Pulses/Revolution].

7.2.2 Stop Current

Stop Current means the motor current value automatically set in 0.5 sec after motor stops. This
is to prevent the overheat of a motor when the motor is under long time idling. Select a desired
Stop Current by pressing
The unit of the selection values is a percentage.
Press
* The default factory setting is 50%.

7.2.3 Pulse Mode

As the pulsed inputs, a user can choose One-pulse-mode (Pulse/Dir) or two-pulse-
mode(CW/CCW). Select a desired pulse mode by pressing
icon on EzStep Setup screen.
Press
* The default factory setting is two pulse input mode (CW/CCW).

7.2.4 Rotation Direction

The direction of the motor rotation can be selected either in CW(clockwise) or in CCW(Counter
Clockwise). Select a desired rotation direction by pressing
icon on EzStep Setup screen.
Press
* The default factory setting is CW(clockwise).
16
in
button to store the value selected into the driver.
in
button to store the value selected into the driver.
button to store the value selected into the driver.
button to store the value selected into the driver.
icon on EzStep Setup
icon on EzStep Setup screen.
in
in

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents