7. Setting Up Parameters

7.1 Setting Up Parameters
RS-232C serial communication port of a computer is used to set up various parameters of
the motor drive. The set-up program is supplied with the product on a companion CD. It is
recommended to make a copy of the program in any folder on your computer. Then please
execute the program, named "Ezi-STEP BT Setting.exe", from the folder.
: Save the parameter values displayed on the screen into the drive.

7.2 Resolution Selection

Resolution means the number of pulses per one rotation of a motor.
Select a desired resolution by pressing
Setting screen. The possible resolution values are 500~50,000.
Press button to save the value selected into the drive.
※ The default factory setting is 10,000[Pulses/Revolution].
: Please select an appropriate Prot No. and press
button. Then it will display the various
parameter values previously stored in the drive.
※ Error Message
There is no response. (You may select wrong baudrate of wrong port
no.) : ① Select wrong Port No.
② Select already used Port No. in other program.
③ Communication cable is not connected.
④ Power is not supplied to drive.
: Display the parameter values stored in the drive.
in
button on Ezi-STEP BT
17 - www.fastech.co.kr