Graco HIGH–FLO 243737 Instructions Manual page 33

Table of Contents

Advertisement

4:1 Ratio King Pumps, Models 243739, 243747, and 243748
Category
Maximum Fluid Working Pressure
Air Operating Range
Fluid Flow at 60 Cycles per Minute
Cycles Per Liter (gallon)
Maximum Recommended Pump
Speed
Wetted parts
Air Motor
40 psi (0.28 MPa, 2.8 bar)
Quiet King
77.9 dB(A)
Air Motor
40 psi (0.28 MPa, 2.8 bar)
Quiet King
85.2 dB(A)
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
Fluid Outlet Pressure
psi
cycles per minute
MPa, bar
10
19
400
2.8, 28
A
300
2.1, 21
B
200
1.4, 14
C
100
0.7, 7
0
0
8
16
gpm
liters/minute
30
60
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
Technical Data
Data
2.8 MPa (28 bar) (400 psi)
0.28–0.7 MPa, 2.8 – 7 bar (40 – 100 psi)
178 liter/min (47 gpm)
0.34 (1.3)
60 cycles per minute
Model 243739: Carbon Steel, Stainless Steel, PTFE,
Ultra High Molecular Weight Polyethylene
Models 243747 and 243748: Stainless Steel, PTFE, Ultra High Molecular
Weight Polyethylene
Sound Pressure Levels (dBa)
(measured at 1 meter from unit)
Input Air Pressures at 15 cycles per minute
70 psi (0.48 MPa, 4.8 bar)
79.2 dB(A)
Sound Power Levels (dBa)
(tested in accordance with ISO 9614–2)
Input Air Pressures at 15 cycles per minute
70 psi (0.48 MPa, 4.8 bar)
86.6 dB(A)
Performance Charts
A
0.6 MPa, 6.2 bar (90 psi) air pressure
B
0.49 MPa, 4.9 bar (70 psi) air pressure
C
0.28 MPa, 2.8 bar (40 psi) air pressure
29
38
48
58
67
24
32
40
48
56
91
121
151
181 212
90 psi (0.6 MPa, 6.2 bar)
87.5 dB(A)
90 psi (0.6 MPa, 6.2 bar)
95.2 dB(A)
To find Pump Air Consumption (m#/min. or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air consumption
curve (dashes). Follow left to scale to read air consumption.
Air Consumption
scfm
cycles per minute
m#/min.
10
19
300
8.5
250
7.1
200
5.7
150
4.3
100
2.8
50
1.4
0
0
8
16
gpm
liters/minute
30
60
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
29
38
48
58
67
A
B
C
24
32
40
48
56
91
121
151
181 212
309136