The tape must be glued smoothly on the surface. The measuring accuracy decreases if the tape is not even!
Before gluing the magnetic tape and the cover tape onto the surface, they should be left lying on the mounting
surface for ca. 30 minutes so that the temperature matches. This prevents strain in the tape due to thermal ex-
pansion.
Mounting steps:
1. Thoroughly clean the surface ( 7.2.3)
2. Acclimatization: let magnetic tape and cover tape adjust their temperature
3. Remove the protection foil from the magnetic tape
4. Glue magnetic tape under great pressure
5. Thoroughly clean surface of magnetic tape
6. Remove the protection foil from the cover tape
7. Glue the cover tape under great pressure
8. Safeguard the ends of the cover tape against peeling off, e.g. by using end caps ( 9.1)
7.2.1
Resistance against Chemical Influence
Table 1: Resistance against Chemical Influence
Show no or little effect in constant contact after 2-5 years:
formic acid
glycerol 93°C
cotton seed oil
N-hexane
formaldehyde 40%
Iso octane
Show weak to moderate effects in constant contact after approximately 1 year:
acetone
gasoline
acetylene
steam
ammonia
acetic acid 20%
kerosene
Have strong effects when contacting permanently after 1-5 months:
benzene
nitric acid 70%
lacquer solvent
nitric acid, red, vitriolic
trichloroethylene
nitrobenzene
linseed oil
lactic acid
petroleum
acetic acid 30%
acetic acid, pure acetic acid
isopropyl ether
turpentine
carbon tetrachloride
hydrochloric acid 37%, 93°C
- 15 -
Installation and First Start-Up
soy beans oil
oleic acid
sea water
stearic acid 70°C, anhydrous
toluene
tetrahydrofuran
xylene