799000215 / Rev. 0 / 2019-05-15 Translation of the original operating manual Operating Manual SERIES PMIX Mechanically guided Incremental Linear Encoder Wear-free alternative to conventional linear measuring systems Also ideally suited as a digital potentiometer replacement Technically based on LMIX resp. EMIX sensors or in combination with a battery powered ELGO display units of the series IZ ...
Contents 1 Contents Contents ..................... 3 General, Safety, Transport and Storage ............ 4 Information Operating Manual ................... 4 Explanation of Symbols ...................... 4 Statement of Warranties ..................... 5 Demounting and Disposal ....................5 General Causes of Risk ..................... 5 Personal Protective Equipment .................... 5 Conventional Use ......................
General, Safety, Transport and Storage 2 General, Safety, Transport and Storage Information Operating Manual This manual contains important information regarding the handling of the device. For your own safety and operational safety, please ob- serve all safety warnings and instructions. Precondition for safe operation is the compliance with the specified safety and handling instruc- tions.
General, Safety, Transport and Storage Statement of Warranties The producer guarantees the functional capability of the process engineering and the selected parameters. Demounting and Disposal Unless acceptance and disposal of returned goods are agreed upon, demount the device considering the safety instructions of this manual and dispose it with respect to the environment.
General, Safety, Transport and Storage CAUTION! Danger through non-conventional use! Non-intended use and non-observance of this operating manual can lead to dangerous situations. Therefore: Only use the device as described Strictly follow the instructions of this manual Avoid in particular: Remodeling, refitting or changing of the construction or single components with the intention to alter the ...
Product Features 3 Product Features General The guided measuring system PMIX is based on the magnetic length measuring systems LMIX or EMIX. Due to the magnetic (and therefore contactless) measuring principle, it is a wear-free alternative to conventional linear encoders. Figure 1: PMIX in combination with an IZ16E display unit Depending on the ordered version, an LMIX, EMIX or EMIX23 sensor can be integrated in the PMIX housing.
Product Features Measuring Systems and Resolutions The PMIX resolution is depending on the selected basis measuring system (see type designation 8). The following table will show all available versions. Table 1: Measuring Systems and Resolutions Measuring System Resolution Magnetic tape pole pitch LMIX 0.1 mm at single edge triggering 5 mm...
Technical Data 4 Technical Data Identification The type label serves for the identification of the unit. It is located on the housing of the sensor and gives the exact type designation ( 8) with the corresponding part number. Furthermore, the type label contains a unique, traceable device number.
Technical Data Technical Data PMIX While the mechanical data at PMIX are fixed, the electrical data differ because they are based on the respective selected measuring system. In addition, there are differences with the variants of supply voltages and output levels.
Technical Data Technical Data Magnetic Tape With a PMIX system, the magnetic tape is already integrated in the guide cylinder and thus must not be installed. The magnetic tape consists of two components: The actual magnetic tape which carries the position information ...
Installation and First Start-Up 5 Installation and First Start-Up CAUTION Please read the operating manual carefully before using the device! Strictly observe the Installation instructions! In case of damage caused by failure to observe this operating manual, the warranty expires. ELGO is not liable for any secondary damage and for damage to persons, property or assets.
Connections 6 Connections Pin assignment with open cable ends (standard) Table 5: Pin Assignment (standard version) Color Function White 0 V (GND) Brow 5 VDC / 10 … 30 VDC in Green Channel A Yellow Channel B Black Channel Z Violet Channel A‘...
Disturbances, Maintenance, Cleaning 7 Disturbances, Maintenance, Cleaning This chapter describes possible causes for disturbances and measures for their removal. In case of increased disturbances, please follow the measures for fault clearance in chapter 7.1. In case of disturbances that cannot be eliminated by following the advice and the fault clear- ance measures given here, please contact the manufacturer (see second page).
Disturbances, Maintenance, Cleaning Maintenance The device is maintenance-free. Cleaning WARNING! The device can only be cleaned with a damp cloth, do not use aggressive cleanser! - 15 -...
Type designation 8 Type designation PMIX BB,B EEEE - Series / Type: PMIX SN Number: ELGO standard First special version, etc. Signal cable length in XX.X m 1,5 m standard length for LMIX/EMIX/EMIX23 1,0 m standard length forIZ14E/IZ15E/IZ16EIZ17E Resolution / basis system: 0,025 mm* with LMIX sensor 0,01 / 0,1 mm** combined with IZ14E 0,01 mm* with EMIX sensor...