Introduction
This user manual serves as a quick reference to the
screen, functions and indicators on your IntelliFire Touch
Remote control.
SCREEN
SCREEN
INDICATOR BAR
ROOM TEMPERATURE
FUNCTIONS
FUNCTIONS
Turn Flame On/Off
Toggle this function to turn ON or OFF your appliance.
IFT-RC400
Model: 2564-110
User Manual
DISPLAY
SELECTION
INDEX
4
3
2
1
OFF
Hearth & Home Technologies • IFT-RC400U User Manual • 2564-983 • 10/20
Thermostat
You can set and maintain your desired room temperature
with the thermostat function. This function automatically
adjusts your appliance to maintain the desired set
temperature (ST).
To achieve the most accurate thermostat function, place
your remote control in the same general space that
you want to have the temperature controlled by your
appliance.
For
best
control away from direct radiant heat from the appliance,
adjacent windows and doors, HVAC vents, and direct
sunlight.
To use the thermostat function, access the main menu
screen on your remote, and select thermostat. Next,
select your desired set temperature and press SET to
confirm the setting. The actual room temperature (RT),
measured by your remote control, will be displayed in
the upper right corner of the main menu screen. To turn
the thermostat function off, select thermostat on the main
menu screen and select OFF in the bottom left corner of
the temperature setting screen.
The thermostat function will automatically adjust the flame
height based on the difference between the RT and the
ST. As the RT rises closer to the ST, the flame height will
automatically adjust down.
During thermostat use, you will not be able to set your
desired flame height level. Your appliance will
automatically adjust flame height based on the difference
between the RT and ST.
results,
keep
your
remote
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IFT-RC400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hearth & Home IFT-RC400

  • Page 1 IFT-RC400 IFT-RC400 IntelliFire Touch Remote Control Model: 2564-110 User Manual Thermostat Introduction You can set and maintain your desired room temperature This user manual serves as a quick reference to the with the thermostat function. This function automatically screen, functions and indicators on your IntelliFire Touch adjusts your appliance to maintain the desired set Remote control.
  • Page 2 RGB Lights FUNCTIONS FUNCTIONS If your appliance is equipped with the RGB lights, you can use this function to adjust the desired intensity when Thermostat with Heat Management appliance is on or off. You will also be able to select one of the seven colors or select a scrolling color spectrum of the seven colors.
  • Page 3: Diagnostics Menu

    RC400 can be used to reset the IFT-WFM to factory de- Refer to Replace Remote Batteries Section. fault settings. To reset the IFT-WFM with the IFT-RC400, while the IFT- Note: To extend the time between replacing batteries, RC400 screen is active, press and hold the “P” button on...
  • Page 4: Backup Battery

    Sorry your appliance did not start. INDICATORS INDICATORS Try again by pressing Flame On. Your appliance did not start during the last Flame On Backup Battery command. Verify that you have power and gas to your appliance. Press the Turn Flame ON icon again, verify The battery life indicator is for a backup power source for that the appliance accepts command with an audible the IFT-ECM located inside your appliance.
  • Page 5 Maintenance INDICATORS INDICATORS Your appliance will remind you to schedule routine ser- vice after 300 hours of Flame ON time is accumulated. Replace Remote Batteries Please contact your dealer for a 300 hour inspection to ensure your appliance is operating at peak performance. Must Replace Remote Batteries to Operate To reset the 300-hour maintenance reminder when the Appliance...
  • Page 6: Frequently Asked Questions/Troubleshooting

    Try to keep the close to the appliance but not di- a very short distance or too far rectly in front of it. The IFT-RC400 acts as the room tempera- away from the appliance. ture sensor when in thermostat mode.
  • Page 7 The IFT-ECM and IFT-RC400 operate on the 915MHz radio unpair from the IFT-ECM. Noisy radio environment is band. Allow up to 10 minutes for the IFT-ECM and IFT-RC400 preventing the IFT-ECM and to establish contact. If the problem does not get resolved try IFT-RC400 from communicating.
  • Page 8 IFT-ACM when the lights are set to highest Ember/backlighting malfunction. level on the IFT-RC400. If the voltage measured is close to 120V AC then power down the appliance and install a new light kit and verify if the issue has been resolved.
  • Page 9: Regulatory Certification

    New Zealand industry standard AS/NZS4268:2014. nected. The IFT-RC400 test reports may be used as part of the • Consult the dealer or an experienced radio/TV product certification and compliance folder. techcian for help...

This manual is also suitable for:

2564-110

Table of Contents