Indoor Unit
KPAV128C5TAA
Outdoor Unit
GRV121L5VAA
RATING CAPACITY
AIR FLOW RATE
EVAPORATOR
ENT.TEMP. °C
W.B.
D.B.
21
23
15
25
27
29
31
21
23
17
25
27
29
31
21
23
19
25
27
29
31
23
21
25
27
29
31
23
25
27
29
31
TC:
TOTAL COOLING CAPACITY
SHC:
SENSIBLE HEAT CAPACITY
CM:
COMPRESSOR INPUT
RATING CONDITIONS
OUTDOOR AMBIENT TEMPERATURE
INDOOR UNIT ENTERING AIR TEMP.
3.3 kW
700 m³/h
OUTDOOR AMBIENT TEMP. °C
25
TC
3.13
CM
1.14
SHC
2.14
SHC
2.43
SHC
2.71
SHC
2.99
SHC
3.13
SHC
3.13
TC
3.39
CM
1.16
SHC
1.88
SHC
2.16
SHC
2.44
SHC
2.72
SHC
3.01
SHC
3.29
TC
3.59
CM
1.22
SHC
1.57
SHC
1.85
SHC
2.12
SHC
2.39
SHC
2.65
SHC
2.93
TC
3.80
CM
1.25
SHC
1.55
SHC
1.82
SHC
2.09
SHC
2.36
SHC
2.63
TC
4.06
CM
1.27
SHC
1.52
SHC
1.78
SHC
2.05
SHC
2.34
kW
kW
kW
CONDENSER
30
35
3.03
2.89
1.21
1.30
2.10
2.03
2.38
2.31
2.65
2.58
2.93
2.86
3.03
2.89
3.03
2.89
3.26
3.10
1.25
1.34
1.82
1.75
2.09
2.02
2.37
2.30
2.65
2.58
2.93
2.86
3.20
3.10
3.47
3.30
1.29
1.38
1.52
1.45
1.80
1.73
2.07
2.00
2.35
2.28
2.63
2.55
2.91
2.83
3.67
3.50
1.32
1.42
1.50
1.43
1.77
1.71
2.05
1.98
2.32
2.26
2.60
2.53
3.89
3.67
1.35
1.46
1.46
1.38
1.73
1.65
2.01
1.93
2.29
2.20
35°C D.B.
27°C D.B./19°C W.B.
29
40
43
2.71
2.50
1.43
1.56
1.94
1.84
2.22
2.12
2.50
2.40
2.71
2.50
2.71
2.50
2.71
2.50
2.91
2.68
1.47
1.60
1.66
1.56
1.94
1.84
2.22
2.11
2.49
2.39
2.77
2.66
2.91
2.68
3.10
2.86
1.51
1.64
1.36
1.26
1.64
1.54
1.92
1.82
2.20
2.09
2.48
2.37
2.75
2.65
3.29
3.03
1.56
1.69
1.34
1.24
1.62
1.52
1.90
1.79
2.17
2.07
2.45
2.35
3.44
3.20
1.59
1.73
1.29
1.21
1.56
1.48
1.84
1.76
2.12
2.04