Technibel KPAV128C5TAA Technical Data & Service Manual page 16

Table of Contents

Advertisement

Outdoor Unit
GRV121L5VAA
Controller PCB
Part No.
Control circuit fuse
Compressor
Type
Compressor model
Nominal output
Compressor oil ... Amount
Coil resistance (Ambient temp. 25°C)
Safety devices
Type
Overload relay
Operating temp.
Operating amp.(Ambient temp. 25°C)
Run capacitor
Crank case heater
Fan & Fan Motor
Type
Q'ty ... Dia.
Fan motor model ... Q'ty
No. of poles ... rpm (230 V, High)
Nominal output
Coil resistance (Ambient temp. 25°C)
Safety devices
Type
Operating temp.
Run capacitor
Heat Exch. Coil
Coil
Rows
Fin pitch
Face area
External Finish
W
cc
Open
°C
Close
°C
Trip in 6 to 16 sec. at 21A
µF
VAC
W
Open
°C
Close
°C
µF
VAC
mm
m
2
12
POW-CLR128E
250 V 3.15 A
Rotary (Hermetic)
C-R110H5HB 80235645B-S
1,100
DAPHNE FV68S ... 510
C–R : 1.962
C–S : 5.38
External(OLR A)
MRA98596-9201
150±5
69±11
25.0
400
240 V 20 W
Propeller
1 ... ø400
KR35410M01846 ... 1
6 ... 770
20
BLK-WHT : 211-242
WHT-VLT : 244-281
VLT-YEL : 83.5-96.1
BLK-PNK : 41.7-48.0
Internal fuse
145±2
2.0
450
Aluminum plate fin / Copper tube
1
1.3
0.379
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
External(OLR T)
CS-7C115
115±3
95±5