2-2-2. Outdoor Unit
Outdoor Unit
GRV71L5VAA
Compressor
Type
Compressor model
Nominal output
Compressor oil ... Amount
Coil resistance (Ambient temp. 25°C)
Safety devices
Type
Overload relay
Operating temp.
Operating amp.(Ambient temp. 25°C)
Run capacitor
Crank case heater
Fan & Fan Motor
Type
Q'ty ... Dia.
Fan motor model ... Q'ty
No. of poles ... rpm (230 V, High)
Nominal output
Coil resistance (Ambient temp. 25°C)
Safety devices
Type
Operating temp.
Run capacitor
Heat Exch. Coil
Coil
Rows
Fin pitch
Face area
External Finish
W
cc
Open
°C
Close
°C
Trip in 6 to 16 sec. at 13A
µF
VAC
W
BLK-WHT : 211-242
VLT-YEL: 83.5-96.1
Open
°C
Close
°C
µF
VAC
mm
2
m
10
Rotary (Hermetic)
C-1RN60H5C 802-060-35B
600
DAPHNE FV68S ... 350
C–R : 4.66
C–S : 8.89
External(OLR A)
MRA38072-3229
145±5
69±11
17.5
450
Propeller
1 ... ø370
KR35410M01846 ... 1
6 ... 770
20
/
/
Internal fuse
150±10
1.5
450
Aluminum plate fin / Copper tube
1
1.3
0.353
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
External(OLR T)
CS-7C115
115±3
95±5
WHT-VLT : 244-281
BLK-PNK : 41.7-48

Advertisement