AEG IAE64851FB User Manual page 12

Table of Contents

Advertisement

12
www.aeg.com
The slider for the active cooking zone
appears on the display and is active for 8
seconds.
3. Touch or slide your finger to set the
desired heat setting.
The symbol turns red and becomes
bigger.
You can also change the heat setting
while cooking. Touch the zone selection
symbol on the main view of the control
panel and move you finger to the left or
right (to lower or increase the heat
setting).
8.4 Using the cooking zones
Place the cookware in the centre of the
selected cooking zone. Induction
cooking zones adapt to the dimensions
of the bottom of the cookware
automatically.
Once you place a pot on the selected
cooking zone the hob automatically
detects it and the relevant slider appears
on the display. The slider is visible for 8
seconds, after that time the display goes
back to the main view. To close the slider
faster tap the screen outside of the slider
area.
When other zones are active the heat
setting for the zone you want to use may
be limited. Refer to "Power
Management".
Make sure that the pot is
suitable for induction hobs.
For more information on
cookware types refer to
"Hints and tips". Check the
size of the pot in "Technical
data".
8.5 PowerBoost
This function activates more power for
the appropriate induction cooking zone;
it depends on the cookware size. The
function can be activated only for a
limited period of time.
1. Touch the desired zone symbol first.
2. Touch
or slide your finger to the
right to activate the function for the
chosen cooking zone.
The symbol turns red and becomes
bigger.
The function deactivates automatically.
To deactivate the function manually
select the zone and change its heat
setting.
For maximum duration
values, refer to "Technical
data".
8.6 Power Management
• Cooking zones are grouped
according to the location and number
of the phases in the hob. See the
illustration.
• Each phase has a maximum electricity
loading of 3680 W.
• The function divides the power
between cooking zones connected to
the same phase.
• The function activates when the total
electricity loading of the cooking
zones connected to a single phase
exceeds 3680 W.
• The function decreases the power of
the other cooking zones connected to
the same phase, which has an
influence on the available heat
setting.
• The maximum heat setting is visible
on the slider. Only the digits in white
are active.
• If a higher heat setting is not available
reduce it for the other cooking zones
first.