Adleepower AP2G3-137 Instruction Manual page 61

General-purpose inverter
Hide thumbs Also See for AP2G3-137:
Table of Contents

Advertisement

Note 1 : The parameter values can be in integer and decimal. Each value
has different process to read and write.
Refer to 8-1 lists to find out the minimum unit and value range
for each parameter.
The following value processing description (Note 2~3), each
hexadecimal value has 4 numbers. First two numbers are D4, last
two numbers are D5.
Note 2 : Processing integer number
Transfer value into hexadecimal value. The first two numbers
is D4 and the last two numbers is D5.
Ex. Speed=1710 rpm
1710(decimal)=06AE(hexadecimal)
D4=06H
D5=AEH
Note 3 : Processing decimal number
Using following methods to process if the minimum parameter
value is decimal number.
Minimum unit by 1
10 to be a new number.
Minimum unit by 2
100 to be a new number.
Then,
Use this new number to tansfer value into hexadecimal value.
Returning numbers to original value, the numbers need to
divide by 10 or 100 if they have been timed by 10 or 100.
The first two numbers is D4 and the last two numbers is D5.
Ex. Acc. time 1 CD02=60.0 sec
60.0
10=600(decimal)=0258(hexadecimal)
×
D4=02H
D5=58H
The value needs to divide by 10 when it returns to original
shape.