Adleepower AP2G3-137 Instruction Manual page 14

General-purpose inverter
Hide thumbs Also See for AP2G3-137:
Table of Contents

Advertisement

(4) Jumper setting
1. JP1 : FT2 over temperature selection
1 and 2 short circuit : PTC temperature switch.
1
2 and 3 short circuit : NTC temperature switch.
2
3
2. JP2 : MET output selection
1 and 2 short circuit : Connect to meter.
1
2 and 3 short circuit : Analog output.
2
3
3. JP3 : Pannel VR and F306 VR selection
AP2G3-137~AP2G3-175, AP2G3-337~AP2G3-375,
AP4G3-337~AP4G3-3110
1 and 2 short circuit : Pannel VR.
1
2 and 3 short circuit : F306 VR.
2
3
4. J3 : RUN/ARR Relay selection
AP2G3-137~AP2G3-175, AP2G3-337~AP2G3-375,
AP4G3-337~AP4G3-3110
5. J4 : RUN/ARR Relay selection
AP2G3-1110~AP2G3-1185, AP2G3-3110~AP2G3-3220,
AP4G3-3150~AP4G3-3220
Up : RUN Relay.
Down : ARR Relay.
Note : When J3 or J4 select ARR, ARR/RUN terminal is RUN open
collector output and MA/MB/MC Relay is ARR.
When J3 or J4 select RUN, ARR/RUN terminal is ARR open
collector output and MA/MB/MC Relay is RUN.
All manuals and user guides at all-guides.com
(0~10VDC refer to 0~CD14)
Left : ARR Relay.
Right : RUN Relay.
12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents