Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Rinnai Manuals
Water Heater
Continuum Series
Service manual
Rinnai Continuum Series Service Manual page 49
Hide thumbs
Also See for Continuum Series
:
Service manual
(63 pages)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
page
of
72
Go
/
72
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
Nature of Fault
Examination Point
Error code "11"
5. Check sparker.
displayed on
digital monitor.
6. Check main gas
solenoid valve (SV0)
Error code 71
7. Check solenoid
valve (SV1)
8. Check changeover
solenoid valve (SV2)
Error code "14"
9. Check thermal fuse
displayed on
digital monitor
10. Check overheat
(remaining flame) bi-
metal switch.
REU-2532FFU Series
Diagnostic Point
1. Measure voltage
between grey ~ grey of
connector F
(sparker)
8
2. # Remove connector
F
and measure the
8
resistance between
sparker terminals.
3. Check if unit is
sparking.
1. # Disconnect the
main solenoid valve
connector E from the
PCB, and measure
resistance between pink
~ black (SV0)
2. Measure voltage
between pink ~ black of
SV0 connector.
1. # Disconnect
connector E from the
PCB. Measure
resistance between
yellow ~ black (SV1)
2. Measure voltage
between yellow ~ black
of SV1 connector.
1. #Disconnect
connector E from PCB.
And measure resistance
between blue ~ black
(SV2)
2. Measure the voltage
between blue ~ black of
SV2 connector.
1. #Disconnect
connector B
and C
3
3
measure resistance
between red ~ red
2. #Disconnect OHS
(remaining flame) bi-
metal switch festoon
terminal B
and C
and
3
3 ,
measure resistance
between terminal on
switch.
49
Values
Y/N
90 ~ 110 VAC
Yes
No
Is resistance >1MΩ
Yes
No
Is the sparker
Yes
sparking?
No
1.7 ~ 2.1KΩ
Yes
No
80 ~ 100 VDC
Yes
No
1.7 ~ 2.1KΩ
Yes
No
80 ~ 100 VDC
Yes
No
1.7 ~ 2.1KΩ
Yes
No
80 ~ 100 VDC
Yes
No
Is resistance <1Ω?
Yes
No
Is resistance <1Ω?
Yes
No
Action
Repair
o
N
Go to B-5-2
Replace PCB
20
Go to B-5-3
Replace sparker.
21
Go to B-6
Adjust/replace
22
electrode.
Go to B-6-2
Replace main
23
solenoid valve
(SV0)
Go to B-7
Replace PCB
24
Go to B-7-2
Replace (SV1)
25
Go to B-8
Replace PCB
26
Go to B-8-2
Replace (SV2)
27
Go to B9
Replace PCB
28
Go to B-10
Replace thermal
29
fuse
Replace PCB
30
Replace
31
remaining flame
bi-metal switch
Rinnai
Table of
Contents
Previous
Page
Next
Page
1
...
46
47
48
49
50
51
52
53
Advertisement
Chapters
Table of Contents
3
Dismantling for Service
54
Table of Contents
Related Manuals for Rinnai Continuum Series
Water Heater Rinnai Continuum Series Service Manual
(63 pages)
Water Heater Rinnai Continuous Flow Water Heaters Operation Manual
Continuous flow water heaters (28 pages)
Water Heater Rinnai RU180i Conversion Manual
For condensing tankless water heaters (16 pages)
Water Heater Rinnai Sensei CU199i Installation And Operation Manual
Tankless water heater (commercial) (96 pages)
Water Heater Rinnai RU130i Installation Instructions Manual
(24 pages)
Water Heater Rinnai CU Series Installation Instructions Manual
Polypropylene (pp) common venting (36 pages)
Water Heater Rinnai V2532FFU Series Operation & Installation Manual
Residential and commercial indoor unit (48 pages)
Water Heater Rinnai CHS199100CU User's Installation And Operation Manual
Commercial hybrid water heating system (52 pages)
Water Heater Rinnai CRYSTAL Series Operation & Installation Manual
Electric instant water heater (23 pages)
Water Heater Rinnai Demand Duo CHS199100HiN Installation And Operation Manual
Commercial hybrid water heating system (56 pages)
Water Heater Rinnai Demand Duo 80 Installation And Operation Manual
(32 pages)
Water Heater Rinnai Demand Duo R-Series Installation And Operation Manual
(52 pages)
Water Heater Rinnai ANS Z21.10.3 Installation And Operation Manual
Direct vent tankless water heater (96 pages)
Water Heater Rinnai RX199i Manual
Tankless water heater (20 pages)
Water Heater Rinnai RX199i Conversion Manual
Tankless water heater, gas conversion (16 pages)
Water Heater Rinnai Demand Duo CX Series Installation Instructions Manual
Commercial hybrid water heating system (56 pages)
Related Products for Rinnai Continuum Series
Rinnai Continuous Flow Water Heaters
Rinnai c199e
Rinnai CRYSTAL Series
Rinnai Demand Duo CHS16080HiN
Rinnai Demand Duo CHS16080HiP
Rinnai Demand Duo CHS19980RiN
Rinnai Demand Duo CHS199100RiP
Rinnai CHS19980HEiP
Rinnai C85e
Rinnai C53iPLUS
Rinnai C85i
Rinnai Demand Duo CHS199100RECiP
Rinnai Demand Duo CHS19980RECiN
Rinnai CU160iN
Rinnai CX160i
Rinnai CU Series
This manual is also suitable for:
Integrity series
Reu2532-ffu
Reu2532-ffu-c
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL