JLG R4045 Operation And Safety Manual page 121

Hide thumbs Also See for R4045:
Table of Contents

Advertisement

DTC
Help Message
POWER MODULE VOLTAGE TOO LOW - MOD-
ULE SHUTDOWN
4424
POWER MODULE - BDI FAULT
4475
BATTERY VOLTAGE TOO HIGH – UNPLUG
CHARGER
4476
BATTERY VOLTAGE TOO HIGH – FORCING DIS-
CHARGE
4477
31215942
SECTION 6 - GENERAL SPECIFICATIONS AND MAINTENANCE
Flash
Alarm
Code
None
4_4
• DriveState = PREVENTED
• LiftUpState = PREVENTED
None
4_4
• DriveState = PREVENTED
• LiftUpState = PREVENTED
None
4_4
• Enter SafeMode
• LiftDownState = MAX
None
4_4
Lift Down = PREVENTED
Lift Up = PREVENTED
Drive = PREVENTED
Action
• Severe B+ Undervoltage Set: Capacitor bank voltage dropped
below Severe Undervoltage limit with FET bridge enabled.
• Effect: Reduced Drive Torque
• Possible Cause:
• Battery menu parameters are misadjusted
• Non-controller system drain on battery
• Battery resisitance too high
• Battery disconnected while driving
• Blown B+ fuse or main contactor not closed
• Pump BDI Fault Set: BDI Percentage charge at 0% when the pump
was activated.
• Effect: ShutdownPump
• Possible Cause:
• Battery is fully discharged
• BDI parameters are mis-tuned
• The Ground Module momentarily measured excessively high battery
voltage (VBAT) (>32.0V) and entered SafeMode to protect system
devices. This may be due to improper battery charging or incorrect
voltage batteries being used.
• The Ground Module momentarily measured excessively high battery
voltage (VBAT) (>32.0V) and entered SafeMode. This may be due to
improper battery charging or incorrect voltage batteries being used.
Trigger
6-29