This product must be installed in strict compliance with
the installation instructions and any applicable local,
state and national codes including, but not limited to
building, electrical, and mechanical codes.
Before performing service or maintenance operations on
unit, turn off main power switch to unit. Electrical shock
could cause personal injury. Improper installation,
adjustment, alteration, service or maintenance can
cause injury or property damage. Refer to this manual.
For assistance or additional information consult a
qualified installer or service agency.
This system uses R-410A Refrigerant which operates at
higher pressures than R-22. No other refrigerant may be
used in this system. Gage sets, hoses, refrigerant
containers and recovery systems must be designed to
handle R-410A. If you are unsure, consult the equipment
manufacturer. Failure to use R-410A compatible servicing
equipment may result in property damage or injury.
Due to system pressure, moving parts, and electrical
components, installation and servicing of air conditioning
equipment can be hazardous. Only qualified, trained service
Nomenclature
Product Category
U = Single Package Heat Pump, R-410A
Product Identifier
Q = 13 SEER Heat Pump
Nominal Cooling Capacity (MBH)
024 = 2.0 Ton
030 = 2.5 Ton
036 = 3.0 Ton
2
U Q 036 C 00
042 = 3.5 Ton
048 = 4.0 Ton
060 = 5.0 Ton
Heat Type & Nominal Heat Capacity
C00 = Cooling Only
Airflow
A = Standard Drive
personnel should install, repair, or service this equipment.
Untrained personnel can perform basic maintenance functions
of cleaning coils and filters and replacing filters.
Observe all precautions in the literature, labels, and tags
accompanying the equipment whenever working on air
conditioning equipment. Be sure to follow all other applicable
safety precautions and codes including.
Wear safety glasses and work gloves. Use quenching cloth and
have a fire extinguisher available during brazing operations.
Inspection
As soon as a unit is received, it should be inspected for possible
damage during transit. If damage is evident, the extent of the
damage should be noted on the carrier's freight bill. A separate
request for inspection by the carrier's agent should be made in
writing.
Reference
Additional information is available in the following reference forms:
• Technical Guide - 546039
• General Installation - 548267
• Electric Heat Accessory - 552392
Renewal Parts
Contact your local York
replacement parts.
Improper installation may create a condition where the
operation of the product could cause personal injury or
property damage.
A
1
A
AA
1 A
1 = First Generation
2 = Second Generation
Additional Options
AA = None
Installation Options
A = No Options Installed
Voltage Code
1 = 208/230-1-60
2 = 208/230-3-60
4 = 460-3-60
548267-YIM-C-0211
®
parts distribution center for authorized
Product Style
A = Style A
Product Generation
Unitary Products Group

Advertisement

Table of Contents
loading

This manual is also suitable for:

Latitude series

Table of Contents