Perkins 1103D Operation And Maintenance Manual page 45

Industrial engine
Table of Contents

Advertisement

SEBU8352-02
Refer to Table 14 for part numbers and for quantities
of SCA.
Table 14
Perkins Liquid SCA
Part Number
21825735
Adding the SCA to Heavy-Duty Coolant
at the Initial Fill
Commercial heavy-duty antifreeze that meets "ASTM
D4985" specifications MAY require an addition of
SCA at the initial fill. Read the label or the
instructions that are provided by the OEM of the
product.
Use the equation that is in Table 15 to determine the
amount of Perkins SCA that is required when the
cooling system is initially filled.
Table 15
Equation For Adding The SCA To The Heavy-Duty Coolant At
The Initial Fill
V × 0.045 = X
V is the total volume of the cooling system.
X is the amount of SCA that is required.
Table 16 is an example for using the equation that is
in Table 15 .
Table 16
Example Of The Equation For Adding The SCA To The Heavy-
Duty Coolant At The Initial Fill
Total Volume of the
Multiplication
Factor
Cooling System (V)
15 L (4 US gal)
× 0.045
Adding The SCA to The Heavy-Duty
Coolant For Maintenance
Heavy-duty antifreeze of all types REQUIRE periodic
additions of an SCA.
Test the antifreeze periodically for the concentration
of SCA. For the interval, refer to the Operation and
Maintenance Manual, "Maintenance Interval
Schedule" (Maintenance Section). Test the
concentration of SCA.
Additions of SCA are based on the results of the test.
The size of the cooling system determines the
amount of SCA that is needed.
Use the equation that is in Table 17 to determine the
amount of Perkins SCA that is required, if necessary:
Quantity
10
Amount of SCA
that is Required (X)
0.7 L (24 oz)
Table 17
Equation For Adding The SCA To The Heavy-Duty Coolant
For Maintenance
V × 0.014 = X
V is the total volume of the cooling system.
X is the amount of SCA that is required.
Table 18 is an example for using the equation that is
in Table 17 .
Table 18
Example Of The Equation For Adding The SCA To The Heavy-
Duty Coolant For Maintenance
Total Volume of the
Multiplication
Cooling System (V)
Factor
15 L (4 US gal)
× 0.014
Cleaning the System of Heavy-Duty
Antifreeze
Perkins cooling system cleaners are designed to
clean the cooling system of harmful scale and
corrosion. Perkins cooling system cleaners dissolve
mineral scale, corrosion products, light oil
contamination and sludge.
• Clean the cooling system after used coolant is
drained or before the cooling system is filled with
new coolant.
• Clean the cooling system whenever the coolant is
contaminated or whenever the coolant is foaming.
45
Maintenance Section
Fluid Recommendations
Amount of SCA
that is Required (X)
0.2 L (7 oz)