5.7

Securing the burner to the boiler

Prepare a suitable lifting system using rings 3)(Fig. 12).
 Fit the heat insulation supplied onto the blast tube 4)
(Fig. 12).
 Fit the entire burner onto the boiler hole prepared previously,
as in Fig. 11, and fasten with the screws supplied.
The seal between burner and boiler must be
airtight.
ATTENTION
5.8

Access to head internal part

In order to reach inside the combustion head (Fig. 13) proceed as
follows:
 disconnect the electrical wiring related to oil pump/
servomotor, air servomotor and gas pressure switch;
 disconnect the leverages related to air damper and head
movement;
 undo the 4 fixing screws 1);
 disconnect the electrode cable 2);
 disconnect the light oil pipes unscrewing the two pipe fittings
3).
Be careful as some drops of fuel may leak out
during this phase.
ATTENTION
 Release the ignition pilot retainer;
 remove the gas pressure screw/test point 6) of the head;
 disconnect the lower part of the elbow until it is released
from its housing;
 remove the internal part of the head 5).
5.9

Electrode position

Position the electrode on ignition pilot according to
the dimensions shown in Fig. 14.
ATTENTION
Installation
7
8
D8364
0
18.5
- 2
Diffuser
17
GB
3
3
1
5
6
2
4
D9337
3
71.5
± 1
Electrode
1
2
5
4
1
Fig. 12
1
Fig. 13
D9218
Fig. 14
20148124

Advertisement

Table of Contents
loading

This manual is also suitable for:

20147802

Table of Contents