Break-In - TOHATSU MFS 25C Owner's Manual

Hide thumbs Also See for MFS 25C:
Table of Contents

Advertisement

32
PRE-OPERATING PREPARATIONS
ENOM00033-A

4. Break-In

Your new outboard motor and lower unit
require break-in for the moving compo-
nents a ccording to the conditions
described in the following time table.
Please refer to ENGINE OPERATION sec-
tion (See page 36) to learn how to cor-
rectly start and operate the outboard
motor.
ENOW00024-A
Do not operate the outboard motor in
6
closed area or area with no forced ventila-
tion.
Exhaust gas emitted by this outboard motor
contains carbon monoxide that will cause
death if inhaled continuously. Inhaling the
gas initially causes symptoms such as feeling
of sickness, drowsiness and headache.
During operation of the outboard motor:
Keep peripheral area well ventilated.
Throttle Position
Speed
DANGER
1–10 min
10 min – 2 hrs
Less than 1/2
Idle
throttle
Approx. 3000
-1
min
(rpm) max
Always attempt to stay on the windward
side of emission.
ENOW00023-1
CAUTION
Operating the outboard motor without
break-in can shorten life.
If any abnormality is experienced during the
break-in:
Discontinue the operation immediately.
Have the dealer check the product and
take proper action(s) if necessary.
ENON00008-1
Note
Run at varied speed less than specified
engine speed during the break-in peri-
ods.
Break-in must be conduct under load
in the water with propeller installed
and in-gear.
2–3 hrs
3–10 hrs
Less than 3/4
3/4 throttle
throttle
Approx. 4000
-1
Full throttle run
min
(rpm). Full
allowed for 1
throttle run
min every 10
allowed for 2
min
min every 10
min
After 10 hrs
Full throttle
available

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfs 30c

Table of Contents