Omron E5 J Series Manual page 14

Fuzzy self-tuning temperature controller with advanced pid (2 pid) contr
Table of Contents

Advertisement

E5jJ
E5CJ-H
(see note 1)
Alarm output 1
E5EJ-H
(see note 1)
Alarm output 1
Set the alarm mode selector 1 to 0 (i.e., no alarm function is ON)
so that alarm output 1 will output only heater burnout alarms.
If the difference in current is small, increase the apparent
electrical current by increasing the number of turns of the heater
wire around the CT. The current displayed by the heater current
value display increases in proportion to the number of turns of
the heater wire.
Use the K2CU-FjjA-jGS (incorporating gate input terminals)
for detecting three-phase heater burnout.
10
5
14
9
4
13
8
3
12
7
2
11
6
1
E5CJ-H
20
10
29
19
9
28
18
8
27
Control output
17
7
26
16
6
25
15
5
24
14
4
CT
23
13
3
22
12
2
21
11
1
E5EJ-H
Note: 1. Alarm 1 is used as heater burnout alarm and temperature alarm
Control output
Heater
+
Heater
+
for models incorporating a heater burnout alarm.
2. Wire through the hole of the Current Transformer. The Current
Transformer and the Temperature Controller can be connected
regardless of polarity.
Output Retention Reset
Once the heater burnout alarm detects heater burnout, alarm output
1 will turn ON. To turn OFF alarm output 1, set the heater burnout
alarm value to 0.0 A or turn off the Temperature Controller and then
turn on the Temperature Controller.
E5jJ
200 VAC
(see note 2)
200 VAC
(see note 2)