Silk'n Lipo H5001 User Manual
Hide thumbs Also See for Lipo H5001:

Advertisement

Quick Links

Lipo
H5001
EN E N
USER MANUAL
EN
BEDIENUNGSANLEITUNG
DE
MODE D'EMPLOI
NL
FR
GEBRUIKSAANWIJZING
ES
NL
MANUAL DEL USUARIO
PT
ES
MANUAL DO UTILIZADOR
PT
GR
ΕΓΧΕΙΡΙ ΙΟ ΧΡΗΣΤΗ
GR
NO
KULLANIM KILAVUZU
FI
TR
MANUALE PER L'UTENTE
IT
SV
BRUKERHÅNDBOK
NO
DA
SV
ANVÄNDARMANUAL
RU
BRUGERMANUAL
DA
DE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lipo H5001 and is the answer not in the manual?

Questions and answers

Summary of Contents for Silk'n Lipo H5001

  • Page 1 Lipo H5001 EN E N USER MANUAL BEDIENUNGSANLEITUNG MODE D’EMPLOI GEBRUIKSAANWIJZING MANUAL DEL USUARIO MANUAL DO UTILIZADOR ΕΓΧΕΙΡΙ ΙΟ ΧΡΗΣΤΗ KULLANIM KILAVUZU MANUALE PER L’UTENTE BRUKERHÅNDBOK ANVÄNDARMANUAL BRUGERMANUAL...
  • Page 2 100-240 Vac 50-60 Hz...
  • Page 3: Table Of Contents

    Table of contents Warnings & contraindications..........2 Safety with Silk'n Lipo ............8 Get to know Silk'n Lipo ............8 Device controls & settings ..........10 Treatment plan ..............14 What to expect with Silk'n Lipo ........15 Get started! ................16 Cleaning & maintenance ..........17 Parts &...
  • Page 4: Warnings & Contraindications

    European Union. When abroad, you must also observe country-specific guidelines and laws. Silk'n Lipo is a powerful electrical device and should be used with special attention to safety. Please read all warnings and contraindications before use. We recommend you familiarise yourself with the instructions in this manual before each treatment.
  • Page 5 Do not reach for the stand/charging cradle or adapter if they have fallen into water. Unplug immediately before retrieving either of them. Failure to unplug the stand/charging cradle may result in an electric shock! Never use the adapter if it has a damaged cable or plug, isn’t working properly, or has been submerged in water.
  • Page 6 Do not use if the parts or accessories are not supplied by the manufacturer as defined in this manual, or if the device is damaged or does not appear to be working properly. In such cases contact Customer Service. Do not clean any of the parts in the dishwasher.
  • Page 7 Attention should be drawn to the environmental aspects of battery disposal. Don’t throw used batteries in a dustbin. Please contact your retailer in order to protect the environment. Battery Removal To remove the battery, the device must be broken apart. The device will no longer function after this procedure, nor can it be repaired.
  • Page 8 Contraindications Silk'n Lipo must not be used by children, adults with limited physical, sensory or psychological capacities, or those lacking experience or knowledge in how to use the device. Keep the device out of the reach of children. Use a lower EMS energy level if you experience any discomfort.
  • Page 9 have applied topical solutions containing metal ions on the treatment area. have epilepsy. have serious arterial circulatory problems in the lower limbs. have an abdominal or inguinal hernia. are pregnant or nursing. Do not use on these parts of the body: Near the heart.
  • Page 10: Safety With Silk'n Lipo

    15 minutes of continuous use. Get to know Silk'n Lipo Silk'n Lipo is a system to help you reduce fat in specific areas, exercise your muscles and tone specific parts of your body without physical effort, and in the comfort of your home.
  • Page 11 * Varies according to the option purchased. 3.2 Device description Silk'n Lipo is a device for home use that utilizes Low Level Laser Technology (LLLT) and Electrical Muscle Stimulation (EMS). Together these energies help increase muscle tone and reduce fatty acids and deposits to enhance body toning and reshaping.
  • Page 12: Device Controls & Settings

    Device controls & settings 4.1 Connecting the different parts Remove the different parts from the box. Place the treatment unit on a flat surface. If you have more than one treatment unit, connect them together. Take the female connector and slot it into the left side of the treatment unit.
  • Page 13 Velcro pad sticks to the belt. Your belt will now look like this. Of course, to use Silk'n Lipo you will need to disconnect one side, place the belt on your body and then reconnect the side you disconnected! Note that you can only use the device when: the treatment unit is charged.
  • Page 14 Control Action Function Turns the treatment unit on (or Control button Long press off). When you turn it on, you will feel a short vibration. When you turn it off, you will feel 2 short vibrations. The green operating light (middle) will be constant green.
  • Page 15 4.3 Energy levels Silk'n Lipo has multiple levels of Electrical Muscle Stimulation (EMS). This gives you excellent control of the intensity of muscle stimulation you wish to use for each part of the body you treat. What's more, you can change levels as often as you like during a treatment.
  • Page 16: Treatment Plan

    Try to avoid gaps and overlaps. Never use Silk'n Lipo on exactly the same spot during a treatment session. For daily use, but no more than 3 times a week on each specific target area. Continue until you get the results you want.
  • Page 17: What To Expect With Silk'n Lipo

    What to expect with Silk'n Lipo If you follow the instructions fully and pay attention to all warnings and contraindications, complications and side effects are uncommon. However, every energy-based device, including those designed for home use, involves some degree of risk. Therefore it is important that you understand and accept the risks and complications that may occur.
  • Page 18: Get Started

    See your doctor if the effects do not go away within 2 to 3 days. Get started! Treating with Silk'n Lipo is easy. Just follow these steps for each part of the body you wish to treat. Use on clean, healthy skin (see section "1. Warnings & contraindications").
  • Page 19: Cleaning & Maintenance

    Changing the EMS level: To increase: Short press the + button as many times as you need to set to the EMS level that is comfortable for you. The operating light blinks more quickly as you increase the EMS level. If you long press the + button, the EMS level will still only increase by one increment.
  • Page 20 Before cleaning: Disconnect the treatment unit from all other parts (belt, electrode pads, connectors, stand/charging cradle). Disconnect the stand/ charging cradle from the electricity supply. Do not use abrasive cleaners or chemicals to clean any parts. Clean each treatment unit and stand/charging cradle with a damp cloth using a mild detergent, then wipe it dry with a clean cloth.
  • Page 21: Parts & Consumables

    8.5 Storage After cleaning, we recommend that you return each treatment unit to the stand/charging cradle. If you do not plan to use the device for a long time, store the different parts in the original packaging in a clean, dry place to prevent the accumulation of dust.
  • Page 22: Customer Service

    11. Customer service For more information see our website www.silkn.eu. This manual is also available as a PDF download from the website. Contact Silk’n Customer Service to report unexpected operations or events, or any other problem with your device. Our contact details are: Country Service number Email...
  • Page 23: Specifications

    14. Specifications H5001 (device); Model No. H5002 (charging cradle) Low Level Laser Therapy (LLLT) Technology Electrical Muscle Stimulation (EMS) Input 12Vdc, 1.5A max Charging cradle Charging 2 modules simultaneously Module powered by Li-ion battery, 3.7V, 2600mA PSM18E-120L6HS Adapter models KSA24A1200150HE Adapter Rating Input: 100-240 Vac, 50-60 Hz, 0.6A Max...
  • Page 24: Signs & Symbols

    Module: 300gr Weight Charging Cradle: 215gr Temperature: minus 40 - 70°C Transport & storage between uses Relative humidity: 10% - 90% and storage condition Atmospheric pressure: 500 - 1060hPa Temperature: 5 - 40°C Operating conditions Relative humidity: 15% - 90% Atmospheric pressure: 700 - 1060hPa Time from minimum storage temperature between uses to...
  • Page 25 © 2018 Home Skinovations Ltd. All rights reserved. Legal Notice Home Skinovations Ltd reserves the right to make changes to its products or specifications to improve performance, reliability, or manufacturability. Information furnished by Home Skinovations Ltd is believed to be accurate and reliable at the time of publication.