Improper connection can result in a risk of an electric shock. Analytic Systems does not recommend the use of the PWS1000 Series Power Supplies in life support ap- plications where failure or malfunction of this product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness.
Introduction The Model FBCS-2K Series Power Supply has been designed to charge forklifts and it is based on two (2) PWS 1000d power supply connected in parallel and placed in a metal enclosure. It supplies 27.2 VDC from a 110 Vac electrical system. A state of the Art Switchmode design offers high reliability, high efficiency and minimum size.
Page 5
18-8 Stainless Weight 12 lb / 5.5 kg * Specifications subjects to change without notice. Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD. 8128 River Way, Delta, B.C., V4G 1K5, Canada phone (604) 946-9981 fax (604) 946-9983 toll free 800-668-3884 US/Canada email: analyticinfo@analyticsystems.com...
Installation ◆ MOUNTING Mount the unit in a DRY location. Allow at least 4 inches of clearance around the heat sink fins for adequate cooling. ◆ POWER CONNECTION The unit is supplied with a 5 foot power cable. This should normally be adequate to connect to a source of power.
Operation Turn the switch on the top of the unit on to energize the outputs. The green indicator light will glow to indicate the proper operation of the unit. ◆ OUTPUT ADJUSTMENT As shipped from the factory, the unit is preset to 13.6, 27.2, 36.3 or 54.4VDC. You may check this voltage at the output terminals of the unit with a good digital voltmeter.
Troubleshooting This unit provides LED indicators and a buzzer to help diagnose any problems. The unit should sound the buzzer to alert you prior to shutting itself down. You should immediately check the indicators to determine the cause of the shutdown. LOW OUTPUT Indicates that the output voltage is below normal because: •...
IMPORTANT: This remote is to be used only on Power Supplies manufactured by Analytic Systems. REMOTE CONNECTOR This connector is located on the side of the unit. Important: To prevent the possibility of High Voltage Electrical Shock, do not power up the Power Supply unless all wiring from the unit to the remote is securely connected.
2 Years from date of manufacture for non-standard or OEM products 1 Year from date of manufacture for encapsulated products. Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card when returned within 30 days, or...
Page 11
Only the Warrantor shall perform warranty service. Any attempt to remedy the defect by anyone else shall render this warranty void. There shall be no warranty for defects or damages caused by faulty installation or hook-up, abuse or misuse of the equipment including exposure to excessive heat, salt or fresh water spray, or water immersion except for equipment specifically stated to be waterproof.