Summary of Contents for Analytic Systems IBI Series

  • Page 1 INSTALLATION & OPERATION MANUAL IBI SERIES IDEAL BATTERY ISOLATOR An ISO9001 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters 101-8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA) www.analyticsystems.com...
  • Page 2 IDEAL BATTERY ISOLATOR MPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS — this manual contains important safety instructions for the Ideal Battery Isolator IDEAL BATTERY ISOLATOR PRECAUTIONS 1. Never place the Ideal Battery Isolator directly above a battery; gases produced from the battery will corrode or damage it.
  • Page 3 Medical Equipment Notice Analytic Systems does not recommend the use of their products in life support applications where failure or malfunction of this product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. Analytic Systems does not recommend the use of any of its products in direct patient care.
  • Page 4 • Front Cover, Product Photo and Title • Product Warnings and Advisories • Table of Contents • Introduction and Box Contents • Main Parts • Operation • Options • Specifications • Warranty Copyright (2005-2021) Analytic Systems Ware (1993) Ltd. Revised - October 26, 2021...
  • Page 5 The box you have received should contain the following: • One IBI Ideal Battery Isolator • This Manual • One Warranty Card If anything is damaged or missing from your box, please contact your dealer or Analytic Systems for a replacement.
  • Page 6 Main Parts Pictured: Top Panel of an IBI3 Top Panel 1. Alternator Positive Connection: 5/16”-18 Silicon-Bronze Hex Bolt 2. Battery Positive Connections: 5/16”-18 Silicon-Bronze Hex Bolt (On the IBI2 model, there are two connection bolts instead of the three pictured.) 3.
  • Page 7 Operation Mounting Mount the unit in a convenient location between your alternator and battery banks, this location should be clear and unobstructed for running cables between the three. If mounting on a metal surface, the ground potential of the surface should be the same as the battery negative.
  • Page 8 Ground Connection The IBI uses a ground reference to operate its control circuitry which it reads through the Ground Connection. To set up this connection: 1. Prepare an AWG18 wire with a #10 lug on one end. 2. Connect this end of the wire to Ground Point. 3.
  • Page 9 Specifications Input IBI2-40-200 IBI2H-40-280 IBI3-40-200 Input Voltage 10-40 VDC for 12, 24, 28 or 32V Battery Systems Input Current 0-200A (Cont.) 0-280A (Cont.) 0-200A (Cont.) Battery Banks Voltage Drop 0.16V @ Max Current Mechanical Length 6.0 in / 15.2cm Width 4.8 in / 12.2cm Height 2.6 in / 6.6cm...
  • Page 10 Page intentionally left blank...
  • Page 11 2 Years from date of manufacture for non-standard or OEM products c. 1 Year from date of manufacture for encapsulated products. 3. Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card when returned within 30 days, or a.
  • Page 12 DESIGNED AND MANUFACTURED BY 800-668-3884 604-946-9983 sales@analyticsystems.com www.AnalyticSystems.com Battery Chargers • Inverters • Power Supplies • Voltage Converters 101-8128 River Way Delta, BC V4G 1K5 | Canada...