4| Compressor assembly
4.5 Operating the shut-off valves
Before opening or closing the shut-off valve, release the valve spindle seal by approx. ¼ of a turn
counter-clockwise.
After activating the shut-off valve, re-tighten the adjustable valve spindle seal clockwise.
Valve spindle seal
Fig. 15
4.6 Operating mode of the lockable service connections
D
GB
F
E
Opening the shut-off valve:
Spindle: turn to the left (counter-clockwise) as far as it will go.
—> Shut-off valve completely opened / service connection closed.
Opening the service connection
Spindle: Turn ½ - 1 turn to the right clockwise.
—> Service connection opened / shut-off valve opened.
12
Fig. 16
Service connec-
tion closed
Spindle
Connection
blocked
Service connec-
tion opened
Connection
Spindle
open
Tighten
Release
Pipe connection
Compressor
Pipe connection
Compressor
Fig. 17