Wpim-E1 Physical Configuration - Enterasys WPIM-E1 Network Manual

Enterasys wpim-e1 interface module: network guide
Table of Contents

Advertisement

The line configuration information shown in Table 2-2 must be supplied
by the service provider.
Table 2-2. Telco Configuration Information
Configuration Information
Required By User
Line Coding
Frame Type
Clock Source
DS-0's (Timeslots)
2.4.1
WPIM-E1 Physical Configuration
Begin the WPIM-E1 configuration by accessing the WAN Physical
Configuration screen through Local Management (Figure 2-1). Proceed
with the following steps:
1. Use the arrow keys to highlight the [WPIM] field at the bottom of the
screen. Press the SPACEBAR to toggle the field to the WPIM being
configured, then press ENTER.
2. Use the arrow keys to highlight Timeslot View. Press the
SPACEBAR to select New, then press ENTER. The cursor moves to
Timeslot #2 of the Timeslot Configuration Table.
3. Insert an interface number (see NOTE below) into every Timeslot
being used (in the example shown in Figure 2-6, 16 Timeslots are
being used, the rest have zeros in them). Type the number, press
ENTER, then use the arrow keys to highlight the next Timeslot field.
Exit this field by using the arrow keys.The cursor automatically moves
to the E1 Line Coding field.
WPIM-E1 LOCAL MANAGEMENT GUIDE
FRACTIONAL E-1 CONFIGURATION USING PPP
Configuration Information
Supplied By Service Provider
HDB3 or AMI
E1 or E1-CRC
Loop Timing or Local Timing
Timeslots being used for each end of
the circuit
2-15