Wpim-E1 Interface Configuration - Enterasys WPIM-E1 Network Manual

Enterasys wpim-e1 interface module: network guide
Table of Contents

Advertisement

2.5.2
WPIM-E1 Interface Configuration
This screen is accessed through the WAN Physical Configuration screen.
Proceed with the following steps to configure the WAN Interface through
Local Management.
1. Set the WAN connection Interface Number by typing the same
number into the Interface Number field that was input into the
Timeslots in the WAN Physical Configuration screen, then press
ENTER. (see NOTE on page 2-20).
2. Use the arrow keys to highlight Line Coding. Press the SPACEBAR
to select None, then press ENTER.
3. Use the arrow keys to highlight Active Protocol. Press the
SPACEBAR to select FR, then press ENTER.
4. Use the arrow keys to highlight FR LMP. Press the SPACEBAR to
select Q.933-A, then press ENTER.
5. Use the arrow keys to highlight the SAVE command, then press
ENTER. The message "Save Done!" appears and Local Management
saves the changes to memory.
Upon saving this screen, the interface just configured is
assigned to an application port (PT#) in the table on the right
NOTE
hand side of the screen once the device starts communicating
with the service provider's switch.
The WAN configuration is complete. Communications between the
WPIM-E1 and the service provider's switch takes approximately 1-2
minutes to begin. A status of Inactive appears until both ends of the PVC
(Permanent Virtual Circuit) are configured. Once both end devices have
negotiated link management with the switches, the status field reads
Active.
WPIM-E1 LOCAL MANAGEMENT GUIDE
FRAME RELAY CONFIGURATION
2-21

Advertisement

Table of Contents
loading

Table of Contents