Viessmann Vitotron 100 Operating Instructions For The System User page 15

Electric instantaneous water boiler for central heating
Table of Contents

Advertisement

Control panel VMN3
Party/Holiday/Manual
Operating mode
The current operating mode of the boiler is shown on
the display. Depending on the boiler configuration, the
following operating modes are available:
(cont.)
Rapid change between operating algorithms as
required.
Party: Set operating mode duration
(from 1 to 24 hours or until changed by the user).
Holiday: Set operating mode duration (from 1 to 60
days or until changed by the user).
Manual: Reach the room temperature set at the
control unit – until changed by the user.
Turbo: Switch on the heating function in the building
with maximum parameters until the set room
temperature is achieved.
Note: This option is only available when the
room temperature drops below the temperature
currently set in the schedule.
* If one of the above operating modes is activated after
calling up the Party/Holiday/Manual settings, it can
be switched off. In manual mode, the set temperature
can also be changed.
* The symbol for the active operating mode is shown
on the main function display.
Standby – central heating and DHW heating
functions are switched off.
Summer – heating function for DHW only.
Note: This function is only available if a DHW
cylinder is installed.
Winter – heating function for central heating and
DHW (if a DHW cylinder is installed).
If the boiler is in standby mode (display off), press the
rotary switch to display the operating mode. To change
the operating mode, press the navigation rotary switch
and select the appropriate position. Select "End" to exit
the settings without changing the operating mode.
Commissioning
If the boiler is being commissioned for the first time
or has been reset to the factory settings, first select
the menu language and then select the boiler output
from the list. Boiler operation cannot be set correctly
until this data has been entered. When commissioning
for the first time with heating circuit modules, first
configure the VCMG3 module (see Chapter 4.2
Configuration mode instructions for VCMG3). Ensure
that a unique identification number is assigned.