5.3 Maintenance

The following inspections and maintenance tasks are recommended at least two
times per year for best controller performance
 Check that the controller is securely mounted in a clean and dry environment
 Check that the air flow and ventilation around the controller is not blocked Clear all
dirt or fragments on the heat sink
 Check all the naked wires to make sure insulation is not damaged for serious
solarization, frictional wear, dryness, insects or rats etc Maintain or replace the wires
if necessary
 Tighten all the terminals Inspect for loose, broken, or burnt wire connections
 Check and confirm that LED digital tube is consistent with required Pay attention to
any troubleshooting or error indication Take necessary corrective action
 Confirm that all the system components are ground connected tightly and correctly
 Confirm that all the terminals have no corrosion, insulation damaged, high
temperature or burnt/discolored sign, tighten terminal screws to the suggested torque
 Inspect for dirt, insects and corrosion, and clear up
 Check and confirm that lightning arrester is in good condition Replace a new one in
time to avoid damaging of the controller and even other equipments
Warning:Risk of electric shock!
Make sure all the power is turned off before above operations, and then follow
the corresponding inspections and operations.