Scanning Options - Viessmann VITOSOLIC 100 Operating Instructions For The System User

Control unit for solar thermal systems
Table of Contents

Advertisement

Displaying actual values
Use
/
to scan the following actual values subject to
the system equipment level:
Note
The flashing sensor symbol in the system scheme
shows the position of the actual temperature.
KOL
Collector temperature in °C (standard display)
TSPU
DHW temperature in °C
S3
Thermostat temperature in °C,
temperature at any additional connected sensor that
may be connected
n1%
Solar circuit pump speed
n2%
Operating condition of the actuator at relay
output R2
hP1
Hours run of the equipment at relay output 1
hP2
Hours run of the equipment at relay output 2
KWh
Amount of heat in kWh, if the heat meter is
enabled
MWh
Amount of heat in MWh, if the heat meter is
enabled
Note
Add the values for MWh and kWh together.
Resetting hours run and amount of heat
Whilst the value is displayed, press the following keys:
1. OK "SET" flashes. Value 0 appears.
2. OK to confirm

Scanning options

5