Siting information
!
Please note
The appliance may suffer damage through the
influence of frost.
Install the heating water buffer cylinder in a
room that is free from the risk of frost and
draughts. When not in use, the heating water
buffer cylinder must be drained if there is a risk
of frost.
Installing the Vitocell with an immersion heater
a
Fig.1
Immersion heater installation instructions
Maintain the minimum clearance.
Note
The unheated length of any threaded immersion
heater installed on site must be at least 100 mm.
Output
Dim. a
Immersion heat-
er
6 kW
min. 500 mm
12 kW
min. 700 mm
Provide adequate clearance from the wall to allow for
■
operation of the temperature controller (if installed).
■
Placing the heating water buffer cylinder on a plinth
will make the room easier to clean.
Dim. b
min. 650 mm
min. 650 mm
Preparing for installation
7