Troubleshooting; Disposal; Cleaning - JAUDT DPK GII 6207 Series Translation Of The Original Operating Instructions

Double shuttle valve
Table of Contents

Advertisement

Operating instructions DPK 6207...
8

Troubleshooting

Fault
Valve does not open or shut
fully
Running noises
Valve stationary/not working
Shaft seal leaking
Pulse generator not issuing any
signals
9

Cleaning

You must not use any cleaners containing acids or lyes, or solvents. Use a wire brush for heavier volumes of
dirt and commercially available cleaners where necessary. Make sure that these are not toxic and cannot
contribute to any toxic compounds. Ensure that they do not contain acids or lyes. Rinse with plenty of drinking
water afterwards.
10

Disposal

Waste oil and lubricants are classified as special waste. Please dispose of them in an environmentally friendly
manner.
Observe the safety and instructions in the same way during disassembly.
© BA_DPK_EN_Rev06-2010.docx
Cause
Encrustations of product on inside
Foreign bodies
Load-limiting device on rocker
arm has tripped
Plate cam or roller is heavily worn
Loose screws (e.g. on safety
covers)
Plate cam or roller is heavily worn
Shaft bearings defective
Gear motor defective
Drive or power supply and
controller defective
Gasket/seal worn
Pulse generator defective
Pulse generator incorrectly
adjusted
End positions are not reached
Remedy
Cleaning
Remove foreign bodies
Reset rocker arm (see piont
5.2)
Check; replace defective parts
Check and secure loose screws
Check; replace defective parts
Repair
Check and repair
Check and repair
Tighten or replace gasket
Replace
Check and set
Reset rocker arm (see piont
5.2)
Page 14 of 18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents