Troubleshooting

Fault
Slide plate leaking outwards
Leak in opening on slide plate
Slide plate jerking or not
moving
Pulse generator not emitting
any signals
© BA_FS140+100_EN_Rev02-2010.doc
verkauf@jaudt.de
Cause
Packing glands worn
Packing glands not leak-tight
Slide plate worn or affected by
caked-on materials
Improper use
Caking on slide plate or housing
Seal in opening worn (where
fitted)
Improper use
Caking on slide plate incl. guides
or in housing
Packing glands worn or subject to
excessive tension
Drive or power supply and control
unit defective
Pulse generator defective
Loose actuating element or
incorrect setting of pulse
generator
End positions are not being
reached
or by fax to ++ 49 (0)821 7960567.
Remedy
Replace packing glands
Tighten packing glands
Clean or replace slide plate
Check working conditions (e.g.
pressure and temperature)
Clean
Fit new seal
Check working conditions (e.g.
pressure and temperature)
Clean
Replace or adjust packing
gland
Check and repair
Renew
Check and adjust
Remove caking or foreign
bodies; check drive and power
supply