Download Print this page

Operating Instructions - Welbilt Cleveland MKEL-40-T Installation, Operation, Maintenance, Parts & Service

Electric vertical mixer kettles

Advertisement

!
WARNING
If for any reason this unit is not
functioning correctly DO NOT
OPERATE. Contact your
authorized service agent.
OPERATING CONTROLS AND INDICATORS
10
11
12
8
13
9
23
ITEM #
DESCRIPTION
1
MAIN POWER SWITCH
2.
MIX/LIFT SWITCH
3.
UP/DOWN SWITCH
4.
MIXER SPEED CONTROL
5.
EMERGENCY STOP BUTTON
6.
HEAT/COOL SWITCH
7.
HEAT/COOL SWITCH
8.
ACTIVE/BYPASS SWITCH
9.
TEMPERATURE CONTROLLER
10.
WATER METER POWER SWITCH
11.
WATER METER START SWITCH
12.
WATER METER INTERRUPT SWITCH
13.
WATER METER CONTROL
15.
MIXER BRIDGE
16.
MAIN AGITATOR ARM
17.
SECONDARY AGITATOR ARM
18.
SECONDARY SPEED CONTROL KNOB
19.
FAUCET SPOUT
20.
HOT WATER VALVE
21.
COLD WATER VALVE
22.
VACUUM/PRESSURE GAUGE
23.
POWER TILT CONTROL SWITCH
24
DRAW OFF VALVE
25.
HEAT INDICATOR LIGHT (GREEN)
26.
SOLID STATE TEMPERATURE
CONTROL KNOB
27.
LOW WATER INDICATOR LIGHT

OPERATING INSTRUCTIONS

17
16
24
FUNCTION
Power switch for unit.
Sets hydraulics to mix or lift mode.
When unit is in lift mode, mixer bridge can be raised or lowered with this switch.
Controls speed of agitators and mixer bridge lift.
Stops hydraulic system (agitators and mixer bridge lift).
Switches left hand kettle from heating to cooling.
Switches right hand kettle from heating to cooling.
Switch to activate or bypass (manual operation) the controller.
Digital temperature control and indicator.
Power switch for water meter.
Starts water flow to kettle.
Interrupts flow without resetting water meter.
Display and settings for water meter.
Encloses agitator motors.
Provides most of the product movement.
Provides reverse agitation and product lift in kettle.
Controls speed of secondary agitator arm.
Delivers water to the kettle.
Turns on hot water.
Turns on cold water.
Indicates steam pressure in PSI inside steam jacket as well as
vacuum in inches of mercury.
Used for tilting the kettle up or down. Replaced by hand tilt wheel on manual tilt units.
Discharge valve for product in the kettle.
When lit, indicates that the kettle burner is on. Cycles ON-OFF with elements.
This control allows the operator to adjust the kettle temperature in increments
from 1 (Min.) to 10 (Max.). (see Temperature Range Chart).
When lit, indicates that the kettle is low on water and will not operate in this
(Red) condition. This will also light when the kettle is tilted.
7.
4
15
18
19
6
20
E M
E R
G E
S T
21
N C
O P
Y
5
1
2
3
19
26
27
7
25

Advertisement

loading