Download Print this page

Welbilt Frymaster Frymaster easyTouch FQG30U Installation, Operation And Maintenance Manual page 49

Hide thumbs Also See for Frymaster Frymaster easyTouch FQG30U:

Advertisement

It is imperative that the fryer system be completely power
60
cycled for at least
seconds after changing oil system type or
waste oil type.
The FilterQuick™ FQ30-T fryers, equipped for use with bulk oil
systems, have an onboard fresh oil jug supplied by the fresh oil
bulk provider. Remove the cap and insert the standard fitting into
the jug with the metal cap resting on the lip of the jug. The oil is
pumped in and out of the jug through the same fitting (see Figure
2).
WARNING
Figure 2
Do not add HOT or USED oil to a top off reservoir.
The momentary switch used to reset the top off reservoir low indicator is also used to
fill the jug in a bulk fresh oil system. After pressing the button to reset the top off
system, pressing and holding the momentary switch, located above the top off
reservoir, allows the operator to fill the jug from the bulk oil storage
tank (see Figure 3).
To fill the jug, press and hold the top off reset button until the jug is
full, then release.*
NOTE: Do NOT overfill the jug.
For instructions on filling the vat from bulk, see Section 2.3.8 in the
FQ4000 Controller manual. To dispose to bulk see section 2.3.13 in
Figure 3
the FQ4000 Controller manual.
* NOTE: It takes approximately twelve seconds from the time the top off reset button
is pressed until the bulk fresh oil pump starts. It may take up to 20 seconds before the
level in the top off reservoir begins to rise.
Typically, it takes approximately three
minutes to fill the reservoir. It takes approximately one minute to fill a split vat and two
minutes to fill a full vat.
A-2