PROBLEM
Frypots won't top
off.
5.5
Troubleshooting Bulk Oil System Problems
PROBLEM
A. Incorrect setup procedure.
Frypot won't
B. Dispose valve not completely
fill.
C. Bulk oil tank is empty.
D. RTI pump issue.
A. Incorrect setup procedure.
Top off
B. Another function is in process.
reservoir won't
C. Dispose valve not completely
fill.
D. Bulk oil tank is empty.
E. Solenoid, pump or switch issue.
Top off
reservoir or vat
filling slow.
PROBABLE CAUSES
A. Fryer temperature too low.
B. Oil is too cold.
C. Top oil empty displayed
D. Service required error exists
E. Melting unit switch is off (only on
solid shortening units)
F. Blown fuse.
PROBABLE CAUSES
closed.
closed.
Pump or line issues beyond the
scope of operator
troubleshooting.
CORRECTIVE ACTION
A. Fryer temperature must be at
setpoint.
B. Ensure that the oil in the top off
reservoir is above 70°F (21°C).
C. Ensure the top off reservoir is
not out of oil. Replace top off
reservoir or fill from bulk and
reset top off system.
If problem persists c all your
FAS for assistance.
D. Call your FAS for assistance.
E. Ensure the switch on the
melting unit is in the ON
position.
F. Check the fuse on the left of the
ATO box. If using a solid
shortening melting unit, check
the fuse below the melting unit
switch.
CORRECTIVE ACTION
A. Power cycle fryer by disconnecting
and reconnecting the bulk oil control
connector on rear of fryer.
B. Ensure the dispose valve handle is
pushed fully closed.
C. Call your bulk oil provider.
D. Call you FAS for assistance.
A. Power cycle fryer by disconnecting
and reconnecting 5-pin bulk oil
control power cord on rear of fryer.
B. If a filtration or any other filter menu
function is in process or FILTER
NOW? YES/NO, CONFIRM YES/NO, or
SKIM VAT are displayed, wait until the
process is complete and try again.
C. Ensure the dispose valve handle is
pushed fully closed.
D. Call your bulk oil provider.
E. Call you FAS for assistance.
Contact your bulk oil provider.