Limpido
EZ
Duo
Electrolysis &
pH regulation
Warning
Carefully read this manual
before installing, starting or
using this device.
Reference
Version
MPET0219
v1.0
Technical Manual v1.0
Technical Data ......................................................................................................... 2
Overview ................................................................................................................. 2
Equipment Description.............................................................................................. 3
Installation............................................................................................................... 4
Start-up ................................................................................................................... 6
Calibration ............................................................................................................... 7
Operation................................................................................................................. 8
Maintenance .......................................................................................................... 11
Date
19/02/2014
Contents

Advertisement

loading

Summary of Contents for ccei Limpido EZ DUO 60

  • Page 1: Table Of Contents

    Technical Manual v1.0 Limpido Electrolysis & pH regulation Warning Carefully read this manual before installing, starting or using this device. Contents Technical Data ......................2 Overview ......................... 2 Equipment Description....................3 Installation....................... 4 Start-up ........................6 Calibration ....................... 7 Operation......................... 8 Maintenance ......................
  • Page 2: Technical Data

    ® Limpido EZ CCEI v1.0 TECHNICAL DATA General Electrolysis EZ Duo 60 EZ Duo 100 pH regulation Dimensions (lxhxd) 260x180x80 Chlorine production 16g/h 24g/h Measurement range 3 to 10 Weight Basin volume 20 to 60m 30 to 100m Precision Power supply...
  • Page 3: Equipment Description

    ® Limpido EZ CCEI v1.0 The main advantage of this operating choice is to guarantee in all cases (even in the case of a power failure) the same normal or reverse production times and, as a result, to ensure the best possible descaling of the cell (enhancing production quality and equipment durability).
  • Page 4: Installation

    ® Limpido EZ CCEI v1.0 INSTALLATION INSTALLING THE PH PROBE The pH probe is installed with a probe holder on a ½’’ dia. clamp. The probe holder must ® be screwed to the clamp with Teflon Loosen the probe holder ring to insert or extract the probe.
  • Page 5 Limpido EZ CCEI v1.0 This contact must be connected to the ″Forced Operation″ terminal strip of the filtration electrical box (Terminal A-B of the CCEI electrical boxes) or to the filtration clock’s contact. ELECTROLYSIS SERVOING CONTACT ® Limpido EZ Duo may be connected to a programmer or a regulator to control production.
  • Page 6: Start-Up

    ® Limpido EZ CCEI v1.0 START-UP WARNING : ONLY REGULAR ANALYSES ALLOW ADAPTING THE DEVICE’S PARAMETERS Scrupulously following the steps below will ensure a trouble-free start-up. CHECKING THE SALT RATIO Limpido EZ Duo is designed to operate with a water conductivity corresponding to a salt content between 2.5g/l and 5g/l at 25°C.
  • Page 7: Calibration

    ® Limpido EZ CCEI v1.0 CALIBRATION Before proceeding with the so-called calibration, it is necessary to : ♦ Set the set point to 7.0 ♦ Stop filtration (flow indicator light turns off) ♦ Take the probe out of the probe holder, and then rinse and dry the probe.
  • Page 8: Operation

    ® Limpido EZ CCEI v1.0 OPERATION ELECTROLYSIS INDICATOR LIGHTS AND BUTTONS Electrolysis and pH regulation operate independently and can be started with the corresponding switch. ® A luminous switch allows switching on the device. The indicator lights indicate the Limpido EZ Duo’s operating state, while the key is used to select its operating mode.
  • Page 9 ® Limpido EZ CCEI v1.0 LOW TEMPERATURE AND TEMPERATURE FAULT In the Automatic mode (thermoregulated), the device stops producing when the temperature is less than 10°C. The thermoregulated indicator light intermittently turns on (1 periodic flash). ® When the temperature rises above 11°C, Limpido EZ Duo automatically resumes the treatment.
  • Page 10 ® Limpido EZ CCEI v1.0 Overproduction Underproduction This alert is generally caused by an excessive To avoid damaging the cell plates during an amount of salt in the pool or an increase of the operation with not enough salt, the device is water temperature.
  • Page 11: Maintenance

    ® Limpido EZ CCEI v1.0 MAINTENANCE SERVICING THE PH PROBE When a pH probe is plunged in water, a film forms around the glass bulb at its end, and this film increases in thickness over time. This invisible film induces an increasingly longer response time, degradation of the slope and a drift from point 0 (pH 7).
  • Page 12 ® Limpido EZ CCEI v1.0 ® IMPIDO Date of sale : ..................Serial number :..................Declaration The Bleu Electrique SAS Company (FR 47 403 521 693) declares that the LIMPIDO EZ Duo product satisfies the safety and electromagnetic compatibility requirements of the European directives 2006/95/EC and 2004/108/EEC.