Please read the following safety information carefully before installing the
switch:
WARNING: Installation and removal of the unit must be carried out by qualified personnel
only.
• This guide is intended for use by network administrators who are responsible for setting up
and installing network equipment; consequently it assumes a basic working knowledge of
LANs (Local Area Networks).
• The unit must be connected to an earthed (grounded) outlet to comply with international
safety standards.
• Do not connect the unit to an A.C. outlet (power supply) without an earth (ground)
connection.
• The appliance coupler (the connector to the unit and not the wall plug) must have a
configuration for mating with an EN 60320/IEC 320 appliance inlet.
• The socket outlet must be near to the unit and easily accessible. You can only remove power
from the unit by disconnecting the power cord from the outlet.
• This unit operates under SELV (Safety Extra Low Voltage) conditions according to
IEC 60950. The conditions are only maintained if the equipment to which it is connected also
operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT
powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point
labelled Neutral, connected directly to earth (ground).
Impédance à la terre
Power Cord Set
U.S.A. and Canada
Denmark
Switzerland
supplies. If your supplies are of IT type, this unit must be
The cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor
The cord set must have a rated current capacity of at least 10 A.
The attachment plug must be an earth-grounding type with NEMA 5-15P
(15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.
The supply plug must comply with Section 107-2-D1, Standard DK2-1a
or DK2-5a.
The supply plug must comply with SEV/ASE 1011.