PRECAUTIONS.........................................................................1
ACCESSORIES (INDOOR UNIT)............................................. 2
INSTALLATING INDOOR UNIT .............................................. 2
INSTALLATING OUTDOOR UNIT.......................................... 4
HEAT INSULATION OF THE PIPE .......................................... 8
INSTALL THE CONNECTIVE PIPE.......................................... 8
INSTALL THE DRAIN PIPE.....................................................10
ELECTRIC CONNECTION.......................................................11
TRIAL RUN .............................................................................12
MAINTENANCE........................................................................13
1.

PRECAUTIONS

Precautions before reading the installation manual.
Read this user manual carefully before installing the equipment.
The air conditioner must be installed by professional technicians.
When installing the indoor unit and its accessory pipes, adhere to
this user's manual as far as possible.
Inspect and make sure the piping and cabling are correct before
powering on the air conditioner.
This information may change with the update of this machine, and
no further notice will be given for such change.
The safety precautions listed here are divided into two categories. In
either case, important safety information is listed which must be read
carefully.
WARNING
Failure to observe a warning may result in death.
CAUTION
Failure to observe a caution may result in injury or damage
to the equipment.
After completing the installation, make sure that the unit operates
properly during the start-up operation. Please instruct the customer
on how to operate the unit and keep it maintained.Also, inform
customers that they should store this installation manual along with
the owner's manual for future reference.
P
A
G
E
Decide the correct way of conveying the equipment.
Try to transport this equipment with the original package.
If the a ir conditioner needs to be installed on a metal part of the
building, electric insulation must be performed, and the installa-
tion must meet the relevant technical standards of electric
devices.
The appliance must be installed 2.3m above floor.
The appliance shall not be installed in the laundry.
Before obtaining access to terminals, all supply circuits
must be disconnected.
The appliance must be positioned so that the plug is
accessible.
The enclosure of the appliance shall be marked by word, or
by symbols, with the direction of the fluid flow.
If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid a hazard.
An all-pole disconnection switch having a contact
separation of at least 3mm in all poles should be
connected in fixed wiring.
Install the unit where enough space of installation and mainte-
nance is available.
Install the unit where the ceiling is horizontal and enough for
bearing the weight of the indoor unit.
Install the unit where the air inlet and outlet are not baffled and
are the least affected by external air.
Install the unit where the supply air flow can be sent to all parts
in the room.
Install the unit where it is easy to lead out the connective pipe
and the drain pipe.
Install the unit where no heat is emitted from a heat source
directly.
WARNING
CAUTION
Installation Manual