  • Page 3: Description Of Appliance

    Operating Instructions Description of appliance Operating modes Light / fan Chimney switches If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be ex- ceeded.
  • Page 4: Safety Instructions

    Before using for the first time Important notes: Safety instructions  The Instructions for Use apply to several ver- Do not flambé food directly under the extractor sions of this appliance. Accordingly, you may hood. find descriptions of individual features that do Risk of grease filter catching fire due to flames.
  • Page 5 Operating the extractor hood Filters and maintenance Grease filters: The most effective method of removing vapours produced during cooking is to: Metal-mesh filters are used to trap the grease  Switch the ventilator ON particles in the cooking vapours. as soon as you begin cooking. The filter mats are made from noncombustible  Switch the ventilator OFF metal.
  • Page 6: Activated Carbon Filter

    Filters and maintenance Filters and maintenance Activated carbon filter:  Remove the filters one by one. For neutralizing odours in recirculating mode. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the hood may be impaired.
  • Page 7: Cleaning And Care

    Cleaning and care Replacing the light bulbs Isolate the extractor hood by pulling out the 1. Switch off the extractor hood and pull out the mains plug or switching off the fuse. mains plug or switch off the electricity supply at  When cleaning the grease filters, remove the fuse box.
  • Page 8: Installation Instructions

    Installation Instructions: Important information Old appliances are not worthless rubbish. Valu- When installing gas hotplates, comply with the able raw materials can be reclaimed by recycling old relevant national statutory regulations (e.g. in Ger- appliances. Before disposing of your old appliance, many: Technische Regeln Gasinstallation TRGI).
  • Page 9: Prior To Installation

    Prior to installation Exhaust-air mode ��� ��� ��� ��� The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open. An air-intake/exhaust-air wall box by itself is no Exhaust air should neither be directed into guarantee that the limiting value will not be ex- a smoke or exhaust flue that is currently used for ceeded.
  • Page 10: Electrical Connection

    Prior to installation Electrical connection  Round pipes: WARNING: THIS APPLIANCE MUST BE We recommend EARTHED Internal diameter: 150 mm (at least 120 mm). IMPORTANT: Fitting a Different Plug:  Flat ducts must have an internal crosssection that equates to that of round pipes. The wires in the mains lead are coloured in accord- There should be no sharp bends.
  • Page 11: Installation

    Electrical connection Installation Ensure that the minimum distance between the Electrical data: hob and the extractor hood is maintained – 400 mm Are to be found on the name plate inside the appli- for the electric or gas hob. ance after removal of the filterframe. 4.
  • Page 12 Installation Connection in Ducting Version with chimney: When installing the ducting version, connect the All the items named in this procedure are hood to the chimney using either a flexible or rigid included in the recirculation kit. The correspond- pipe ø 150 or 120 mm, the choice of which is left to ing accessory numbers can be found at the end the installer.
  • Page 13: Chimney Assembly

    Installation Chimney assembly The chimney cannot be installed in recircu- lation hood with the filter cover.  Fasten the angle iron 15 to the hood canopy using the screws 12d provided. �� ��� �� Upper Chimney ��� �����  Slightly widen the two sides of the upper Chim- ney and hook them behind the brackets 7.2.1, making sure that they are well seated.